Low tube voltage improves computed tomography imaging of delayed myocardial contrast enhancement in an experimental acute myocardial infarction model

被引:74
作者
Mahnken, Andreas H.
Bruners, Philipp
Muehlenbruch, Georg
Emmerich, Melanie
Hohl, Christian
Guenther, Rolf W.
Wildberger, Joachim E.
机构
[1] Univ Aachen, Rhein Westfal TH Aachen, Dept Diagnost Radiol, D-5100 Aachen, Germany
[2] Univ Aachen, Rhein Westfal TH Aachen, Helmholtz Inst, D-5100 Aachen, Germany
关键词
computed tomography; heart; myocardial infarction; animal experimentation; contrast media;
D O I
10.1097/01.rli.0000251577.68223.84
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Objective: We sought to evaluate the influence of tube voltage on the visualization of acute myocardial infarction (MI) in cardiac multislice spiral computed tomography (MSCT). Materials and Methods: Acute MI was induced in 12 domestic pigs by a 45-minute balloon occlusion of the left anterior descending artery. Delayed enhancement magnetic resonance imaging was performed 15 minutes after the injection of 0.2 mmol/kg Gd-DTPA. On the same day.. retrospectively ECG-gated MSCT was performed at 120, 100, and 80 kV (16 x 0.75mm, 550mAs(eff)) 15 minutes after the injection of 140 mL of iopromide (1 g/iodine/kg). The pigs were killed and the hearts were excised and stained with 2,3,5-triphenyltetrazolium chloride. The area of acute MI, contrast-to-noise ratio (CNR), and percent signal difference were compared among the different imaging techniques by applying Bland-Altman plots and 2-way analysis of variance. Results: On MSCT at 120, 100, and 80 kV, the respective mean acute MI sizes were 18.4 +/- 11.4%, 19.3 +/- 11.5%, and 20.5 +/- 11.6%. The mean MI sizes were 20.8 +/- 12.2% and 20.1 +/- 12.4% on magnetic resonance imaging and 2,3,5-triphenyltetrazolium chloride staining. Analysis of variance did not show any statistically significant differences between the different techniques with respect to the size of acute MI (P = 0.9880). Comparing the different kV settings on MSCT, the highest percent signal difference (74.7 +/- 12.1%) and the highest CNR (6.7 +/- 1.8) between infarcted and healthy remote myocardium were achieved at 80 kV. Conclusions: When compared with routine scan protocols, low tube voltage MSCT allows for the assessment of the MI size with an improved CNR and contrast resolution. This technique appears to be advantageous for assessing myocardial viability from contrast enhanced late-phase MSCT.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 25 条
[1]
Improved vascular opacification in cerebral computed tomography angiography with 80 kVp [J].
Bahner, ML ;
Bengel, A ;
Brix, G ;
Zuna, I ;
Kauczor, HU ;
Delorme, S .
INVESTIGATIVE RADIOLOGY, 2005, 40 (04) :229-234
[2]
Multislice computed tomography and magnetic resonance imaging for the assessment of reperfused acute myocardial infarction [J].
Baks, Timo ;
Cademartiri, Filippo ;
Moelker, Amber D. ;
Weustink, Annick C. ;
van Geuns, Robert-Jan ;
Mollet, Nico R. ;
Krestin, Gabriel P. ;
Duncker, Dirk J. ;
de Feyter, Pim J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (01) :144-152
[3]
A feasibility study of contrast enhancement of acute myocardial infarction in multislice computed tomography -: Comparison with magnetic resonance imaging and gross morphology in pigs [J].
Buecker, A ;
Katoh, M ;
Krombach, GA ;
Spuentrup, E ;
Bruners, P ;
Günther, RW ;
Niendorf, TF ;
Mahnken, AH .
INVESTIGATIVE RADIOLOGY, 2005, 40 (11) :700-704
[4]
Contrast agents and cardiac MR imaging of myocardial ischemia: from bench to bedside [J].
Croisille, Pierre ;
Revel, Didier ;
Saeed, Maythem .
EUROPEAN RADIOLOGY, 2006, 16 (09) :1951-1963
[5]
Characterization of acute and chronic myocardial infarcts by multidetector computed tomography - Comparison with contrast-enhanced magnetic resonance [J].
Gerber, BL ;
Belge, B ;
Legros, GJ ;
Lim, P ;
Poncelet, A ;
Pasquet, AS ;
Gisellu, G ;
Coche, E ;
Vanoverschelde, JLJ .
CIRCULATION, 2006, 113 (06) :823-833
[6]
THROMBOLYSIS AND MYOCARDIAL SALVAGE - RESULTS OF CLINICAL-TRIALS AND THE ANIMAL PARADIGM - PARADOXIC OR PREDICTABLE [J].
GERSH, BJ ;
ANDERSON, JL .
CIRCULATION, 1993, 88 (01) :296-306
[7]
UPTAKE OF CONTRAST MATERIALS BY EXPERIMENTAL ACUTE MYOCARDIAL INFARCTIONS - PRELIMINARY-REPORT [J].
HIGGINS, CB ;
SOVAK, M ;
SCHMIDT, W ;
SIEMERS, PT .
INVESTIGATIVE RADIOLOGY, 1978, 13 (04) :337-339
[8]
Estimation of radiation exposure in low-dose multislice computed tomography of the heart and comparison with a calculation program [J].
Hohl, C. ;
Muehlenbruch, G. ;
Wildberger, J. E. ;
Leidecker, C. ;
Suss, C. ;
Schmidt, T. ;
Guenther, R. W. ;
Mahnken, A. H. .
EUROPEAN RADIOLOGY, 2006, 16 (08) :1841-1846
[9]
Phase-sensitive inversion recovery (PSIR) single-shot TrueFISP for assessment of myocardial infarction at 3 tesla [J].
Huber, A ;
Bauner, K ;
Wintersperger, BJ ;
Reeder, SB ;
Stadie, F ;
Mueller, E ;
Schmidt, M ;
Winnik, E ;
Reiser, MF ;
Schoenberg, SO .
INVESTIGATIVE RADIOLOGY, 2006, 41 (02) :148-153
[10]
Technique factors and image quality as functions of patient weight at abdominal CT [J].
Huda, W ;
Scalzetti, EM ;
Levin, G .
RADIOLOGY, 2000, 217 (02) :430-435