Estimation of radiation exposure in low-dose multislice computed tomography of the heart and comparison with a calculation program

被引:36
作者
Hohl, C.
Muehlenbruch, G.
Wildberger, J. E.
Leidecker, C.
Suss, C.
Schmidt, T.
Guenther, R. W.
Mahnken, A. H.
机构
[1] Univ Technol Aachen, Dept Diagnost Radiol, D-52057 Aachen, Germany
[2] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
[3] Siemens Med Solut Comp Tomog, D-91301 Forchheim, Germany
关键词
dose reduction; MSCT; low-kV scan protocol; calculation program; cardiac;
D O I
10.1007/s00330-005-0124-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the achievable organ dose savings in low-dose multislice computed tomography (MSCT) of the heart using different tube voltages (80 kVp, 100 kVp, 120 kVp) and compare it with calculated values. A female Alderson-Rando phantom was equipped with thermoluminescent dosimeters (TLDs) in five different positions to assess the mean doses within representative organs (thyroid gland, thymus, oesophagus, pancreas, liver). Radiation exposure was performed on a 16-row MSCT scanner with six different routine scan protocols: a 120-kV and a 100-kV CT angiography (CTA) protocol with the same collimation, two 120-kV Ca-scoring (CS) protocols with different collimations and two 80-kV CS protocols with the same collimation as the 120-kV CS protocols. Each scan protocol was repeated five times. The measured dose values for the organs were compared with the values calculated by a commercially available computer program. Directly irradiated organs, such as the esophagus, received doses of 34.7 mSv (CTA 16x0.75 120 kVp), 21.9 mSv (CTA 16x0.75 100 kVp) and 4.96 mSv (CS score 12x1.5 80 kVp), the thyroid as an organ receiving only scattered radiation collected organ doses of 2.98 mSv (CTA 16x0.75 120 kVp), 1.97 mSv (CTA 16x0.75 100 kVp) and 0.58 mSv (CS score 12x1.5 80 kVp). The measured relative organ dose reductions from standard to low-kV protocols ranged from 30.9% to 55.9% and were statistically significant (P < 0.05). The comparison with the calculated organ doses showed that the calculation program can predict the relative dose reduction of cardiac low photon-energy protocols precisely.
引用
收藏
页码:1841 / 1846
页数:6
相关论文
共 21 条
[1]  
Becker C, 1999, ROFO-FORTSCHR RONTG, V170, P99
[2]   Effective doses in standard protocols for multi-slice CT scanning [J].
Cohnen, M ;
Poll, LW ;
Puettmann, C ;
Ewen, K ;
Saleh, A ;
Mödder, U .
EUROPEAN RADIOLOGY, 2003, 13 (05) :1148-1153
[3]   Radiation exposure in multi-slice CT of the heart [J].
Cohnen, M ;
Poll, L ;
Püttmann, C ;
Ewen, K ;
Mödder, U .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (04) :295-299
[4]   Performance evaluation of a 64-slice CT system with z-flying focal spot [J].
Flohr, T ;
Stierstorfer, K ;
Raupach, R ;
Ulzheimer, S ;
Bruder, H .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (12) :1803-1810
[5]   Automatic exposure control to reduce the dose in subsecond multislice spiral CT: Phantom measurements and clinical results [J].
Greess, H ;
Wolf, H ;
Suess, C ;
Kalender, WA ;
Bautz, W ;
Baum, U .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (06) :862-869
[6]   16-detector multislice CT: dosimetry estimation by TLD measurement compared with Monte Carlo simulation [J].
Groves, AM ;
Owen, KE ;
Courtney, HM ;
Yates, SJ ;
Goldstone, KE ;
Blake, GM ;
Dixon, AK .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (920) :662-665
[7]   Radiation dose reduction to the male gonads during MDCT:: The effectiveness of a lead shield [J].
Hohl, C ;
Mahnken, AH ;
Klotz, E ;
Das, M ;
Stargardt, A ;
Mühlenbruch, G ;
Schmidt, T ;
Günther, RW ;
Wildberger, JE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (01) :128-130
[8]   Technique factors and image quality as functions of patient weight at abdominal CT [J].
Huda, W ;
Scalzetti, EM ;
Levin, G .
RADIOLOGY, 2000, 217 (02) :430-435
[9]   Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT [J].
Hunold, P ;
Vogt, FM ;
Schmermund, A ;
Debatin, JF ;
Kerkhoff, G ;
Budde, T ;
Erbel, R ;
Ewen, K ;
Barkhausen, J .
RADIOLOGY, 2003, 226 (01) :145-152
[10]   Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating [J].
Jakobs, TF ;
Wintersperger, BJ ;
Herzog, P ;
Flohr, T ;
Suess, C ;
Knez, A ;
Reiser, MF ;
Becker, CR .
EUROPEAN RADIOLOGY, 2003, 13 (08) :1923-1930