Candidate image processing for real-time volumetric CT subtraction angiography

被引:6
作者
Mori, Shinichiro
Endo, Masahiro
机构
[1] National Institute of Radiological Sciences, Research Center for Charged Particle Therapy
[2] National Institute of Radiological Sciences, Department of Planning and Management
关键词
angiography; CT; image processing; subtraction;
D O I
10.1016/j.ejrad.2006.09.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Since a 256-slice CT can perform real time observation of the volumetric cine images at multiple angles, volumetric CT angiography can provide much useful clinical information. Conventional CT subtraction angiography is generated by subtracting the non-enhanced CT image (mask CT image) from each contrast-enhanced CT image. Since even conventional CT subtraction angiography takes a few minutes to compute the image, volumetric CT subtraction angiography images require computation of an enormous amount of volumetric cine data (image base CT subtraction angiography: ICTSA) which means an excessively long calculating time. To reduce calculating time, we developed the raw data base CT subtraction angiography (RCTSA) that subtracts raw data instead of the reconstructed four-dimensional image sets. Image quality of the two image processing methods was evaluated in phantom and animal studies. Evaluation items were image noise, CT number uniformity, and subtracting RCTSA from ICTSA. ICTSA calculates the number of volume data; however, RCTSA uses the number of CT rotations. Moreover, since RCTSA can also be started subtraction early in the process of data acquisition, it reduced the number of calculations considerably. As there is a longer CT acquisition time, RCTSA shortens the ratio of the calculating time compared to that of ICTSA. RCTSA is useful image processing to reduce CT subtraction angiography examination time instead of ICTSA. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:335 / 341
页数:7
相关论文
共 21 条
[1]   Development and performance evaluation of the first model of 4-D CT-scanner [J].
Endo, M ;
Mori, S ;
Tsunoo, T ;
Kandatsu, S ;
Tanada, S ;
Aradate, H ;
Saito, Y ;
Miyazaki, H ;
Satoh, K ;
Matsusita, S ;
Kusakabe, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1667-1671
[2]  
ENDO M, 2006, IEEE NSS MIC C REC, pM11
[3]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[4]  
Knauth M, 1997, AM J NEURORADIOL, V18, P1001
[5]   Real-time volumetric imaging of human heart without electrocardiographic gating by 256-detector row computed tomography - Initial experience [J].
Kondo, C ;
Mori, S ;
Endo, M ;
Kusakabe, K ;
Suzuki, N ;
Hattori, A ;
Kusakabe, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (05) :694-698
[6]   Three-dimensional CT with a modified C-arm image intensifier: Feasibility [J].
Linsenmaier, U ;
Rock, C ;
Euler, E ;
Wirth, S ;
Brandl, R ;
Kotsianos, D ;
Mutschler, W ;
Pfeifer, KJ .
RADIOLOGY, 2002, 224 (01) :286-292
[7]   Improved motion compensation in 3D-CT using respiratorycorrelated segment reconstruction: diagnostic and radiotherapy applications [J].
Mori, S. ;
Endo, M. ;
Kohno, R. ;
Minohara, S. .
BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (945) :745-755
[8]   Physical evaluation of CT scan methods for radiation therapy planning: comparison of fast, slow and gating scan using the 256-detector row CT scanner [J].
Mori, S ;
Kanematsu, N ;
Mizuno, H ;
Sunaoka, M ;
Endo, M .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (03) :587-600
[9]   Prototype heel effect compensation filter for cone-beam CT [J].
Mori, S ;
Endo, M ;
Nishizawa, K ;
Ohno, M ;
Miyazaki, H ;
Tsujita, K ;
Saito, Y .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (22) :N359-N370
[10]  
Mori S, 2005, AM J NEURORADIOL, V26, P2536