Comparison of efficiency and preference of metal and plastic spacers in preschool children

被引:7
作者
Amirav, I [1 ]
Tiosano, T
Chamny, S
Chirurg, S
Oren, S
Grossman, Z
Kahan, E
Newhouse, MT
Mansour, Y
机构
[1] Sieff Hosp Safed, Safed, Israel
[2] IPROS Network Israel Ambulatory Pediat Assoc, Petah Tiqwa, Israel
[3] Schneider Childrens Med Ctr Israel, Petah Tiqwa, Israel
[4] McMaster Univ, Hamilton, ON, Canada
关键词
D O I
10.1016/S1081-1206(10)61496-2
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background: The metal NebuChamber valved holding chamber (VHC) has gained wide acceptance among children with asthma. Due to its nonelectrostatic properties and larger volume, the 250-mL, metal NebuChamber delivers a greater mass of aerosol to a filter at the mouth compared with the commonly used 150-mL polypropylene AeroChamber VHC. Such in vitro results have been used to suggest that this may provide increased efficacy with the NebuChamber. No comparative efficacy data exist for preschool children with asthma. Objective: To compare efficiency and preference of metal and plastic spacers in preschool children. Methods: Children with mild-to-moderate persistent asthma received 200 mug of budesonide twice daily by NebuChamber or AeroChamber, both with the mask provided in a randomized, 2-month, crossover trial. Symptom diary cards, beta-agonist use, and preference by children and parents were compared. Results: Thirty children (mean +/- SD age, 4.3 +/- 0.3 years) completed the study. There was no difference between the AeroChamber and NebuChamber in clinical efficacy outcomes. There was no difference between the AeroChamber and NebuChamber in parents' view of ease of use, design, acceptability by the children, and overall satisfaction. Conclusions: Despite a greater total dose delivered to the mouth, the NebuChamber appears no more effective than the AeroChamber and it is not preferred by patients or parents. More parents chose to continue to use the NebuChamber after the study.
引用
收藏
页码:249 / 252
页数:4
相关论文
共 27 条
[1]  
AMIAV I, 2004, PEDIAT PULMONOL, V37, P172
[2]   Safe of inhaled corticosteroids delivered by plastic and meta spacers [J].
Amirav, I ;
Mansour, Y ;
Tiosano, T ;
Chamny, S ;
Chirurg, S ;
Oren, S ;
Grossman, Z ;
Kahana, L ;
Kahan, E ;
Newhouse, MT .
ARCHIVES OF DISEASE IN CHILDHOOD, 2003, 88 (06) :527-528
[3]   Aerosol therapy with valved holding chambers in young children: Importance of the facemask seal [J].
Amirav, I ;
Newhouse, MT .
PEDIATRICS, 2001, 108 (02) :389-394
[4]   THE EFFECT OF DELAY, MULTIPLE ACTUATIONS AND SPACER STATIC CHARGE ON THE IN-VITRO DELIVERY OF BUDESONIDE FROM THE NEBUHALER [J].
BARRY, PW ;
OCALLAGHAN, C .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1995, 40 (01) :76-78
[5]   The output of budesonide from spacer devices assessed under simulated breathing conditions [J].
Barry, PW ;
O'Callaghan, C .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1999, 104 (06) :1205-1210
[6]   In vitro performance of three combinations of spacers and pressurized metered dose inhalers for treatment in children [J].
Berg, E ;
Madsen, J ;
Bisgaard, H .
EUROPEAN RESPIRATORY JOURNAL, 1998, 12 (02) :472-476
[7]   The effect of inhaled fluticasone propionate in the treatment of young asthmatic children - A dose comparison study [J].
Bisgaard, H ;
Gillies, J ;
Groenewald, M ;
Maden, C .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 160 (01) :126-131
[8]  
BISGAARD H, 1995, EUR RESPIR J, V8, P856
[9]   A NONELECTROSTATIC SPACER FOR AEROSOL DELIVERY [J].
BISGAARD, H ;
ANHOJ, J ;
KLUG, B ;
BERG, E .
ARCHIVES OF DISEASE IN CHILDHOOD, 1995, 73 (03) :226-230
[10]  
Borgstrom L, 1998, J AEROSOL MED, V11, pS59