Relationship between bone-prosthesis bonding and load transfer in total hip reconstruction

被引:77
作者
McNamara, BP
Cristofolini, L
Toni, A
Taylor, D
机构
[1] RIZZOLI ORTHOPAED INST, BIOMAT TECHNOL LAB, BOLOGNA, ITALY
[2] UNIV BOLOGNA, FAC ENGN, BOLOGNA, ITALY
[3] UNIV DUBLIN TRINITY COLL, DEPT MECH ENGN, DUBLIN 2, IRELAND
关键词
experimental model; finite element model; femur analogue; total hip replacement; bonding; load transfer;
D O I
10.1016/S0021-9290(97)00003-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The effect of bone-prosthesis bonding on proximal load transfer is investigated using a coupled experimental and finite element analysis on a synthetic femur. Three-dimensional finite element models for an intact femur and a femur implanted with a cementless prosthesis were constructed from the experimental models used, and the proximal femoral strains recorded for two loading conditions approximating a one-legged stance. The approach was used to investigate a press-fitted and a fully bonded bone-prosthesis structure to identify the stem-bone behaviour for both interface conditions and their implications for proximal bone load transfer. Regression slopes close to unity indicated that the finite element predictions were an accurate estimate of the experimental measurements. Physiological surface strains were recorded only when the abductor force was included in the loading, Meanwhile, experimental measurements and numerical predictions showed that a different load transfer pattern is to be expected for normally press-fitted and glued press-fitted stems. The finite element model for the treated femur, modelling both interface conditions correlated very well with the experimental model. These finite element models subsequently modified and used to analyse the effect of different interface conditons predicted a significant increase in the load transfer to the proximal calcar bone when only proximal bonding is achieved. This study suggests that information obtained for the assessment and prediction of total hip arthroplasty longevity by numerical and experimental techniques used together and in parallel is of greater value than either technique used alone. The employment of a femur analogue as featured in this study is also shown to be a suitable alternative to cadaveric specimens in such an analysis. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:621 / 630
页数:10
相关论文
共 39 条
[1]  
BARICH FE, 1995, T 41 ORS OR, P268
[2]   HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[3]   DETERMINATION OF TRANSVERSE ELASTIC COEFFICIENTS OF BONE [J].
BERME, N ;
MENGI, Y ;
INGER, E .
JOURNAL OF BIOMECHANICS, 1977, 10 (10) :643-&
[4]   STEM CURVATURE AND LOAD ANGLE INFLUENCE THE INITIAL RELATIVE BONE-IMPLANT MOTION OF CEMENTLESS FEMORAL STEMS [J].
BERZINS, A ;
SUMNER, DR ;
ANDRIACCHI, TP ;
GALANTE, JO .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1993, 11 (05) :758-769
[5]  
BIANCO PT, 1989, T ASME BIOMECHANICS, P297
[6]  
CARTER DR, 1978, CLIN ORTHOP RELAT R, V135, P192
[7]   TELEMETRIC FORCE MEASUREMENTS ACROSS THE HIP AFTER TOTAL ARTHROPLASTY [J].
DAVY, DT ;
KOTZAR, GM ;
BROWN, RH ;
HEIPLE, KG ;
GOLDBERG, VM ;
HEIPLE, KG ;
BERILLA, J ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (01) :45-50
[8]  
ENGH CA, 1990, CLIN ORTHOP RELAT R, V261, P63
[9]   PROXIMAL FEMORAL SURFACE STRAIN-GAUGE ANALYSIS OF A NEW EPIPHYSEAL PROSTHESIS [J].
FIELD, RE ;
RUSHTON, N .
JOURNAL OF BIOMEDICAL ENGINEERING, 1989, 11 (02) :123-129
[10]   AN EVALUATION OF 3 LOADING CONFIGURATIONS FOR THE INVITRO TESTING OF FEMORAL STRAINS IN TOTAL HIP-ARTHROPLASTY [J].
FINLAY, JB ;
CHESS, DG ;
HARDIE, WR ;
RORABECK, CH ;
BOURNE, RB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (05) :749-759