Femoral shaft fracture resulting from femoral tracker placement in navigated TKA

被引:65
作者
Bonutti, Peter [1 ]
Dethmers, Daniel [1 ]
Stiehl, James B. [2 ]
机构
[1] St Antonys Hosp, Effingham, IL USA
[2] Columbia St Marys Hosp, Dept Orthopaed Surg, Med Coll Wisconsin, Milwaukee, WI USA
关键词
D O I
10.1007/s11999-008-0150-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Computer-assisted navigation is a surgical tool that may decrease malalignment outliers in TKA. With any new surgical technique, there is the possibility of unexpected complications that raise caution. We report two patients with displaced femoral fractures at optical tracker pin placement sites created for routine performance of navigated TKA. Our experience suggests single bicortical 5-mm pins placed in the femoral shaft have the added risk of creating a stress riser leading to the potential for fracture. Females may have a higher risk for this complication. We believe bicortical pin fixation in the femur or tibia no longer is indicated.
引用
收藏
页码:1499 / 1502
页数:4
相关论文
共 21 条
[1]
Computer navigation versus standard instrumentation for TKA - A single-surgeon experience [J].
Bolognesi, M ;
Hofmann, A .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) :162-169
[2]
BIOMECHANICS OF TORSIONAL FRACTURES - STRESS CONCENTRATION EFFECT OF A DRILL HOLE [J].
BROOKS, DB ;
BURSTEIN, AH ;
FRANKEL, VH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1970, A 52 (03) :507-&
[3]
BONE STRENGTH - EFFECT OF SCREW HOLES [J].
BURSTEIN, AH ;
VESSELY, JC ;
FRANKEL, VH ;
LUNSETH, P ;
CURREY, J ;
HEIPLE, KG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1972, 54 (06) :1143-+
[4]
Computer-assisted total knee replacement - A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT protocol) [J].
Chauhan, SK ;
Clark, GW ;
Lloyd, S ;
Scott, RG ;
Breidahl, W ;
Sikorski, JM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (06) :818-823
[5]
Leg axis after computer-navigated total knee arthroplasty - A prospective randomized trial comparing computer-navigated and manual implantation [J].
Decking, R ;
Markmann, Y ;
Fuchs, J ;
Puhl, W ;
Scharf, HP .
JOURNAL OF ARTHROPLASTY, 2005, 20 (03) :282-288
[6]
TIBIAL FRACTURE THROUGH A TRACTION-PIN SITE - A REPORT OF 2 CASES [J].
EVANS, PEL ;
THOMAS, WG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (09) :1475-1476
[7]
Computer-assisted navigation increases precision of component placement in total knee arthroplasty [J].
Haaker, RG ;
Stockheim, M ;
Kamp, M ;
Proff, G ;
Breitenfelder, J ;
Ottersbach, A .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (433) :152-159
[8]
CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT [J].
JEFFERY, RS ;
MORRIS, RW ;
DENHAM, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :709-714
[9]
Johnson B A, 1997, J Foot Ankle Surg, V36, P446
[10]
Fractures associated with computer-navigated total knee arthroplasty [J].
Jung, Ho-Joong ;
Jung, Young-Bok ;
Song, Kwang-Sup ;
Park, Se-Jin ;
Lee, Jong-Seok .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (10) :2280-2284