Rates of glucose change measured by blood glucose meter and the GlucoWatch Biographer during day, night, and around mealtimes

被引:30
作者
Dunn, TC [1 ]
Eastman, RC [1 ]
Tamada, JA [1 ]
机构
[1] Cygnus, Redwood City, CA 94063 USA
关键词
D O I
10.2337/diacare.27.9.2161
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - The purpose of this study was to characterize the distribution of the rate of change of blood glucose for a diabetic population. RESEARCH DESIGN AND METHODS - The study population consisted of 124 adults with type 1 or type 2 diabetes requiring insulin. Study participants applied a GlucoWatch Biographer during the day at home for 5 consecutive days and took finger-prick blood glucose measurements hourly. Subjects kept a diary of meals. The Biographer frequently and automatically measured glucose Lip to three times per hour for up 12 h. Rates of glucose change were calculated for both Biographer and blood glucose measurements. Rates of glucose change during a separate study of 134 subjects were determined for daytime and nighttime use. RESULTS - Mean (+/- SD) rates of change of glucose of -0.36 +/- 0.95 and 0.36 +/- 0.99 mg dl(-1.)min(-1) were found before and after lunch using blood glucose data and -0.31 +/- 1.23 and 0.43 +/- 1.26 using Biographer data. For both types of diabetes, rates of glucose change exceeded 2 mg(.)dl(-1.)min(-1) before and after meals similar to10% of the time. Periprandial glucose patterns showed some significant differences between type 1 and type 2 diabetic subjects. Glucose levels changed more gradually at night than during the day. CONCLUSIONS - Glucose values were almost unstable before and after meals. Glycemic instability around dinner was different in type 1 and type 2 diabetes. The GlucoWatch Biographer was found to be effective in tracking trends in glucose levels and yielded similar results as obtained by finger-prick blood samples.
引用
收藏
页码:2161 / 2165
页数:5
相关论文
共 13 条
[1]  
Eastman Richard C, 2002, Pediatr Diabetes, V3, P127, DOI 10.1034/j.1399-5448.2002.30302.x
[2]   Rapid changes in postprandial blood glucose produce concentration differences at finger, forearm, and thigh sampling sites [J].
Ellison, JM ;
Stegmann, JM ;
Colner, SL ;
Michael, RH ;
Sharma, MK ;
Ervin, KR ;
Horwitz, DL .
DIABETES CARE, 2002, 25 (06) :961-964
[3]   Use of an automated device for alternative site blood glucose monitoring [J].
Fineberg, SE ;
Bergenstal, RM ;
Bernstein, RM ;
Laffel, LM ;
Schwartz, SL .
DIABETES CARE, 2001, 24 (07) :1217-1220
[4]   Correlation at fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes [J].
Garg, SK ;
Potts, RO ;
Ackerman, NR ;
Fermi, SJ ;
Tamada, JA ;
Chase, HP .
DIABETES CARE, 1999, 22 (10) :1708-1714
[5]   NONINVASIVE SAMPLING OF BIOLOGICAL-FLUIDS BY IONTOPHORESIS [J].
GLIKFELD, P ;
HINZ, RS ;
GUY, RH .
PHARMACEUTICAL RESEARCH, 1989, 6 (11) :988-990
[6]   Glucose monitoring at the arm - Risky delays of hypoglycemia and hyperglycemia detection [J].
Jungheim, K ;
Koschinsky, T .
DIABETES CARE, 2002, 25 (06) :956-960
[7]   Physiological differences between interstitial glucose and blood glucose measured in human subjects [J].
Kulcu, E ;
Tamada, JA ;
Reach, G ;
Potts, RO ;
Lesho, MJ .
DIABETES CARE, 2003, 26 (08) :2405-2409
[8]   REVERSE IONTOPHORESIS - DEVELOPMENT OF A NONINVASIVE APPROACH FOR GLUCOSE MONITORING [J].
RAO, G ;
GLIKFELD, P ;
GUY, RH .
PHARMACEUTICAL RESEARCH, 1993, 10 (12) :1751-1755
[9]   THE EFFECT OF INTENSIVE TREATMENT OF DIABETES ON THE DEVELOPMENT AND PROGRESSION OF LONG-TERM COMPLICATIONS IN INSULIN-DEPENDENT DIABETES-MELLITUS [J].
SHAMOON, H ;
DUFFY, H ;
FLEISCHER, N ;
ENGEL, S ;
SAENGER, P ;
STRELZYN, M ;
LITWAK, M ;
WYLIEROSETT, J ;
FARKASH, A ;
GEIGER, D ;
ENGEL, H ;
FLEISCHMAN, J ;
POMPI, D ;
GINSBERG, N ;
GLOVER, M ;
BRISMAN, M ;
WALKER, E ;
THOMASHUNIS, A ;
GONZALEZ, J ;
GENUTH, S ;
BROWN, E ;
DAHMS, W ;
PUGSLEY, P ;
MAYER, L ;
KERR, D ;
LANDAU, B ;
SINGERMAN, L ;
RICE, T ;
NOVAK, M ;
SMITHBREWER, S ;
MCCONNELL, J ;
DROTAR, D ;
WOODS, D ;
KATIRGI, B ;
LITVENE, M ;
BROWN, C ;
LUSK, M ;
CAMPBELL, R ;
LACKAYE, M ;
RICHARDSON, M ;
LEVY, B ;
CHANG, S ;
HEINHEINEMANN, M ;
BARRON, S ;
ASTOR, L ;
LEBECK, D ;
BRILLON, D ;
DIAMOND, B ;
VASILASDWOSKIN, A ;
LAURENZI, B .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (14) :977-986
[10]   Noninvasive glucose monitoring - Comprehensive clinical results [J].
Tamada, JA ;
Garg, S ;
Jovanovic, L ;
Pitzer, KR ;
Fermi, S ;
Potts, RO .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 282 (19) :1839-1844