Development of binding assays in microfabricated picoliter vials: An assay for biotin

被引:23
作者
Grosvenor, AL
Feltus, A
Conover, RC
Daunert, S [1 ]
Anderson, KW
机构
[1] Univ Kentucky, Dept Chem & Mat Engn, Lexington, KY 40506 USA
[2] Univ Kentucky, Dept Chem, Lexington, KY 40506 USA
[3] Univ Kentucky, Dept Pharmaceut Sci, Lexington, KY 40506 USA
关键词
D O I
10.1021/ac991289+
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A homogeneous binding assay for the detection of biotin in picoliter vials was developed using the photoprotein aequorin as the label. The binding assay was based on the competition of free biotin with biotinylated aequorin (AEQ-biotin) for avidin. A sequential protocol was used, and modification of the assay to reduce the number of steps was examined. Results showed that detection limits on the order of 10(-14) mol of biotin were possible. Reducing the number of steps provided similar detection limits but only if the amount of avidin used was decreased. These binding assays based on picoliter volumes have potential applications in a variety of fields, including microanalysis and single-cell analysis, where the amount of sample is limited. In addition, these assays are suitable for the high-throughput screening of biopharmaceuticals.
引用
收藏
页码:2590 / 2594
页数:5
相关论文
共 30 条
[1]   COVALENT IMMOBILIZATION OF AVIDIN ON GLASSY-CARBON ELECTRODES AS THE BASIS FOR MULTIVALENT BIOSENSORS [J].
ACHTNICH, UR ;
TIEFENAUER, LX ;
ANDRES, RY .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (04) :279-290
[2]  
Blinks J.R., 1978, Methods in Enzymology, V57, P292
[3]  
BLINKS JR, 1989, METHOD ENZYMOL, V172, P165
[4]   Micromachining sensors for electrochemical measurement in subnanoliter volumes [J].
Bratten, CDT ;
Cobbold, PH ;
Cooper, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :253-258
[5]   EXPRESSION AND SECRETION OF AEQUORIN AS A CHIMERIC ANTIBODY BY MEANS OF A MAMMALIAN EXPRESSION VECTOR [J].
CASADEI, J ;
POWELL, MJ ;
KENTEN, JH .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (06) :2047-2051
[6]   Chemical analysis of single cells and exocytosis [J].
Chen, GY ;
Ewing, AG .
CRITICAL REVIEWS IN NEUROBIOLOGY, 1997, 11 (01) :59-90
[7]   Electrochemical analysis in picoliter microvials [J].
Clark, RA ;
Hietpas, PB ;
Ewing, AG .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :259-263
[8]  
CROFCHECK CL, 1997, ANAL CHEM, V69, P4766
[9]  
Ewing Andrew G., 1994, Analytical Chemistry, V66, P527
[10]   MICROCOLUMN SAMPLE INJECTION BY SPONTANEOUS FLUID DISPLACEMENT [J].
FISHMAN, HA ;
SCHELLER, RH ;
ZARE, RN .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :99-107