Development of binding assays in microfabricated picoliter vials: An assay for biotin

被引:23
作者
Grosvenor, AL
Feltus, A
Conover, RC
Daunert, S [1 ]
Anderson, KW
机构
[1] Univ Kentucky, Dept Chem & Mat Engn, Lexington, KY 40506 USA
[2] Univ Kentucky, Dept Chem, Lexington, KY 40506 USA
[3] Univ Kentucky, Dept Pharmaceut Sci, Lexington, KY 40506 USA
关键词
D O I
10.1021/ac991289+
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A homogeneous binding assay for the detection of biotin in picoliter vials was developed using the photoprotein aequorin as the label. The binding assay was based on the competition of free biotin with biotinylated aequorin (AEQ-biotin) for avidin. A sequential protocol was used, and modification of the assay to reduce the number of steps was examined. Results showed that detection limits on the order of 10(-14) mol of biotin were possible. Reducing the number of steps provided similar detection limits but only if the amount of avidin used was decreased. These binding assays based on picoliter volumes have potential applications in a variety of fields, including microanalysis and single-cell analysis, where the amount of sample is limited. In addition, these assays are suitable for the high-throughput screening of biopharmaceuticals.
引用
收藏
页码:2590 / 2594
页数:5
相关论文
共 30 条
[21]  
MILLER AL, 1994, METHOD CELL BIOL, V40, P305
[22]   Patterning of functional antibodies and other proteins by photolithography of silane monolayers [J].
Mooney, JF ;
Hunt, AJ ;
McIntosh, JR ;
Liberko, CA ;
Walba, DM ;
Rogers, CT .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (22) :12287-12291
[23]   QUANTITATIVE TRACE-ELEMENT ANALYSIS OF MICRODROPLET RESIDUES BY SECONDARY ION MASS-SPECTROMETRY [J].
ODOM, RW ;
LUX, G ;
FLEMING, RH ;
CHU, PK ;
NIEMEYER, IC ;
BLATTNER, RJ .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :2070-2075
[24]   Ordered nanowell arrays [J].
Pantano, P ;
Walt, DR .
CHEMISTRY OF MATERIALS, 1996, 8 (12) :2832-2835
[25]   Amperometry and cyclic voltammetry of tyrosine and tryptophan-containing oligopeptides at carbon fiber microelectrodes applied to single cell analysis [J].
Paras, CD ;
Kennedy, RT .
ELECTROANALYSIS, 1997, 9 (03) :203-208
[26]   RAPID CHANGES OF MITOCHONDRIAL CA2+ REVEALED BY SPECIFICALLY TARGETED RECOMBINANT AEQUORIN [J].
RIZZUTO, R ;
SIMPSON, AWM ;
BRINI, M ;
POZZAN, T .
NATURE, 1992, 358 (6384) :325-327
[27]   A SHORT-STORY OF AEQUORIN [J].
SHIMOMURA, O .
BIOLOGICAL BULLETIN, 1995, 189 (01) :1-5
[28]   BIOLUMINESCENCE BINDING ASSAY FOR BIOTIN WITH ATTOMOLE DETECTION BASED ON RECOMBINANT AEQUORIN [J].
WITKOWSKI, A ;
RAMANATHAN, S ;
DAUNERT, S .
ANALYTICAL CHEMISTRY, 1994, 66 (11) :1837-1840
[29]   INDIRECT FLUORESCENCE DETERMINATION OF LACTATE AND PYRUVATE IN SINGLE ERYTHROCYTES BY CAPILLARY ELECTROPHORESIS [J].
XUE, QF ;
YEUNG, ES .
JOURNAL OF CHROMATOGRAPHY A, 1994, 661 (1-2) :287-295
[30]   Complexometric determination of metal ions by microscopic diffusional titration [J].
Yi, C ;
Huang, DJ ;
Gratzl, M .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1580-1584