Comparison of low-contrast detail detectability with five different conventional and digital radiographic imaging systems

被引:13
作者
Neitzel, U [1 ]
Böhm, A [1 ]
Maack, I [1 ]
机构
[1] Philips Med Syst, D-22331 Hamburg, Germany
来源
MEDICAL IMAGING 2000: IMAGE PERCEPTION AND PERFORMANCE | 2000年 / 3981卷
关键词
low-contrast detectability; digital radiography; image noise; observer performance;
D O I
10.1117/12.383113
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Five different X-ray imaging systems were evaluated comparatively with respect to few-contrast detail detectability. The systems included in this study were two screen-film systems (speed classes 200 and 400), a computed radiography system, a digital selenium-based system with electrometer scanning and an indirect-type flat-panel detector system. Images of a contrast-detail phantom were acquired with all systems at a set of exactly matched exposures, The digital images were processed in a way to approximate the density and contrast appearance of the conventional Afm images when printed on laser film. Six observers evaluated a total number of 46 films with respect to the threshold contrast for each detail size. Correct observation ratios and threshold contrasts were determined for all sizes and conditions. The overall results show that the low-contrast detectability with all digital imaging systems is equal to or better than that with the conventional film-screen systems. The advantage is more evident for the newer digital systems (selenium detector and flat-panel detector) where as the CR images are more on a par with the conventional films. The results can be understood assuming that low-contrast detection is limited mainly by quantum noise in the images and taking into account the different levels of detective quantum efficiency of these imaging systems.
引用
收藏
页码:216 / 223
页数:8
相关论文
共 18 条
[1]  
[Anonymous], 1994, 1267 IEC
[2]   Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography [J].
Aufrichtig, R .
MEDICAL PHYSICS, 1999, 26 (07) :1349-1358
[3]  
BUNCH PC, 1994, P SOC PHOTO-OPT INS, V2163, P14, DOI 10.1117/12.174255
[4]   New CsI/a-Si 17" x 17" X-ray flat panel detector provides superior detectivity and immediate direct digital output for General Radiography systems [J].
Chaussat, C ;
Chabbal, J ;
Ducourant, T ;
Spinnler, V ;
Vieux, G ;
Neyret, R .
PHYSICS OF MEDICAL IMAGING, 1998, 3336 :45-56
[5]   COMPARISON OF THE LOW-CONTRAST DETECTABILITY OF A SCREEN-FILM SYSTEM AND 3RD-GENERATION COMPUTED RADIOGRAPHY [J].
COOK, LT ;
INSANA, MF ;
MCFADDEN, MA ;
HALL, TJ ;
COX, GG .
MEDICAL PHYSICS, 1994, 21 (05) :691-695
[6]   THRESHOLD PERCEPTION PERFORMANCE WITH COMPUTED AND SCREEN-FILM RADIOGRAPHY - IMPLICATIONS FOR CHEST RADIOGRAPHY [J].
DOBBINS, JT ;
RICE, JJ ;
BEAM, CA ;
RAVIN, CE .
RADIOLOGY, 1992, 183 (01) :179-187
[7]  
DOBBINS JT, 1998, P SPIE, V3336
[8]  
DOBBINS JT, 1999, P SPIE, V3659
[9]   A comparison of the physical imaging properties of Fuji ST-V, ST-VA, and ST-VN computed radiography image plates [J].
Kengyelics, SM ;
Davies, AG ;
Cowen, AR .
MEDICAL PHYSICS, 1998, 25 (11) :2163-2169
[10]   Image quality evaluation of a direct digital radiography detector operating in a UK radiology department [J].
Kengyelics, SM ;
Cowen, AR ;
Davies, AG .
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 :24-35