ESI-MS/MS library of 1,253 compounds for application in forensic and clinical toxicology

被引:83
作者
Dresen, Sebastian [1 ]
Gergov, Merja [2 ]
Politi, Lucia [3 ,4 ]
Halter, Claudia [1 ]
Weinmann, Wolfgang [1 ]
机构
[1] Univ Freiburg, Med Ctr, Inst Forens Med, D-79104 Freiburg, Germany
[2] Univ Helsinki, Dept Forens Med, SF-00300 Helsinki, Finland
[3] Univ Florence, Dept Anat Histol & Legal Med, Div Forens Toxicol, Florence, Italy
[4] Univ Pavia, Dept Legal Med & Publ Hlth, I-27100 Pavia, Italy
关键词
Mass spectral library; Forensics/toxicology; Drug monitoring/drug screening; Clinical/biomedical analysis; CHROMATOGRAPHY-MASS SPECTROMETRY; INTER-LABORATORY TRANSFERABILITY; PRODUCT ION SPECTRA; DRUG IDENTIFICATION; SEARCH; INTERINSTRUMENT; TRAP;
D O I
10.1007/s00216-009-3084-2
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
An electrospray ionization tandem mass spectrometry (ESI-MS/MS) library which contains over 5,600 spectra of 1,253 compounds relevant in clinical and forensic toxicology has been developed using a hybrid tandem mass spectrometer with a linear ion trap. Pure compound solutions-in some cases solutions made of tablets-were prepared and 1 to 2,000 ng of each compound were injected into the system using standard reversed-phase analytical columns with gradient elution. To obtain maximum mass spectral information enhanced product ion spectra were acquired with positive and/or negative ionization at low, medium, and high collision energies and additionally applying collision energy spread. In this mode, all product ions generated by the different collision energies are trapped in the linear ion trap prior to their detection. The applicability of the library for other types of hybrid tandem mass spectrometers with a linear ion trap of the same manufacturer as well as a standard triple-quadrupole tandem mass spectrometer has been investigated with a selection of compounds. The spectra of the developed library can be used to create methods for target analysis, either screening methods or quantitative procedures by generating transitions for multiple reaction monitoring. For those procedures, suitable transitions and convenient collision energies are selected from the library. It also has been utilized to identify compounds with a multi target screening approach for clinical and forensic toxicology with a standardized and automated system. The novel aspects compared to our former library produced with a standard triple-quadrupole mass spectrometer are the enlargement of the ESI-MS/MS library and the additional acquisition of spectra with collision energy spread.
引用
收藏
页码:2521 / 2526
页数:6
相关论文
共 20 条
[1]
Reproducible product-ion tandem mass spectra on various liquid chromatography/mass spectrometry instruments for the development of spectral libraries [J].
Bristow, AWT ;
Webb, KS ;
Lubben, AT ;
Halket, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (13) :1447-1454
[2]
Information-dependent acquisition-mediated LC-MS/MS screening procedure with semiquantitative potential [J].
Decaestecker, TN ;
Casteele, SRV ;
Wallemacq, PE ;
Van Peteghem, CH ;
Defore, DL ;
Van Bocxlaer, JF .
ANALYTICAL CHEMISTRY, 2004, 76 (21) :6365-6373
[3]
Electrospray-ionization MS/MS library of drugs as database for method development and drug identification [J].
Dresen, Sebastian ;
Kempf, Juergen ;
Weinmann, Wolfgang .
FORENSIC SCIENCE INTERNATIONAL, 2006, 161 (2-3) :86-91
[4]
Gergov M, 2000, J MASS SPECTROM, V35, P912, DOI 10.1002/1096-9888(200007)35:7<912::AID-JMS19>3.0.CO
[5]
2-4
[6]
Comparison of product ion spectra obtained by liquid chromatography/triple-quadrupole mass spectrometry for library search [J].
Gergov, M ;
Weinmann, W ;
Meriluoto, J ;
Uusitalo, J ;
Ojanperä, I .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (10) :1039-1046
[7]
Simultaneous screening for 238 drugs in blood by liquid chromatography-ionspray tandem mass spectrometry with multiple-reaction monitoring [J].
Gergov, M ;
Ojanperä, I ;
Vuori, E .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 795 (01) :41-53
[8]
Towards a universal product ion mass spectral library - reproducibility of product ion spectra across eleven different mass spectrometers [J].
Hopley, Chris ;
Bristow, Tony ;
Lubben, Anneke ;
Simpson, Alec ;
Bul, Elaine ;
Klagkou, Katerina ;
Herniman, Julie ;
Langley, John .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (12) :1779-1786
[9]
Creation and comparison of MS/MS spectral libraries using quadrupole ion trap and triple-quadruople mass spectrometers [J].
Josephs, JL ;
Sanders, M .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (07) :743-759
[10]
Comparison of a preliminary procedure for the general unknown screening of drugs and toxic compounds using a quadrupole-linear ion-trap mass spectrometer with a liquid chromatography-mass spectrometry reference technique [J].
Marquet, P ;
Saint-Marcoux, F ;
Gamble, TN ;
Leblanc, JCY .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 789 (01) :9-18