Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis

被引:232
作者
Lagally, ET [1 ]
Emrich, CA
Mathies, RA
机构
[1] Univ Calif Berkeley, UC Berkeley UC San Francisco Joint Bioengn Grad G, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, UC Berkeley Biophys Grad Grp, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
来源
LAB ON A CHIP | 2001年 / 1卷 / 02期
关键词
D O I
10.1039/b109031n
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fully integrated genomic analysis microsystem including microfabricated heaters, temperature sensors, and PCR chambers directly connected to capillary electrophoretic separation channels has been constructed. Valves and hydrophobic vents provide controlled and sensorless sample positioning and immobilization into 200 nL PCR chambers. The use of microfabricated heating and temperature sensing elements improves the heating and cooling rates for the PCR reaction to 20 degreesC s(-1). The amplified PCR product, labeled on-column with an intercalating fluorescent dye, is injected into the gel-filled capillary for electrophoretic analysis. Successful sex determination using a multiplex PCR reaction from human genomic DNA is demonstrated in less than 15 min. This device is an important step toward a microfabricated genomic microprocessor for use in forensics and point-of-care molecular medical diagnostics.
引用
收藏
页码:102 / 107
页数:6
相关论文
共 28 条
  • [1] A miniature integrated device for automated multistep genetic assays
    Anderson, Rolfe C.
    Su, Xing
    Bogdan, Gregory J.
    Fenton, Jeffery
    [J]. NUCLEIC ACIDS RESEARCH, 2000, 28 (12)
  • [2] Belgrader P, 1998, J FORENSIC SCI, V43, P315
  • [3] Silicon microchambers for DNA amplification
    Daniel, JH
    Iqbal, S
    Millington, RB
    Moore, DF
    Lowe, CR
    Leslie, DL
    Lee, MA
    Pearce, MJ
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1998, 71 (1-2) : 81 - 88
  • [4] The stability of Pt heater and temperature sensing elements for silicon integrated tin oxide gas sensors
    Esch, H
    Huyberechts, G
    Mertens, R
    Maes, G
    Manca, J
    De Ceuninck, W
    De Schepper, L
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2000, 65 (1-3) : 190 - 192
  • [5] HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION
    HJERTEN, S
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02): : 191 - 198
  • [6] Real-time microchip PCR for detecting single-base differences in viral and human DNA
    Ibrahim, MS
    Lofts, RS
    Jahrling, PB
    Henchal, EA
    Weedn, VW
    Northrup, MA
    Belgrader, P
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (09) : 2013 - 2017
  • [7] Chemical amplification: Continuous-flow PCR on a chip
    Kopp, MU
    de Mello, AJ
    Manz, A
    [J]. SCIENCE, 1998, 280 (5366) : 1046 - 1048
  • [8] Monolithic integrated microfluidic DNA amplification and capillary electrophoresis analysis system
    Lagally, ET
    Simpson, PC
    Mathies, RA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (03): : 138 - 146
  • [9] Single-molecule DNA amplification and analysis in an integrated microfluidic device
    Lagally, ET
    Medintz, I
    Mathies, RA
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (03) : 565 - 570
  • [10] Moore J.H., 1989, BUILDING SCI APPARAT, V2nd