X-ray detection characteristics of thallium bromide nuclear radiation detectors

被引:10
作者
Hitomi, K [1 ]
Muroi, O [1 ]
Matsumoto, M [1 ]
Hirabuki, R [1 ]
Shoji, T [1 ]
Hiratate, Y [1 ]
机构
[1] Tohoku Inst Technol, Dept Elect, Taihaku Ku, Sendai, Miyagi 9828577, Japan
关键词
D O I
10.1109/23.856514
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Semiconductor X-ray detectors have been fabricated from high purity TlBr crystals grown by the traveling molten zone method. X-ray detection characteristics of the TlBr detectors in the individual quantum pulse mode as well as in the current mode have been studied. An energy resolution of 2.5 keV FWHM has been recorded for 22 keV X-rays with a TlBr detector operated in the individual quantum pulse mode at room temperature. The TlBr detectors in the current mode have been tested as flux detectors for an X-ray CT scanner system of a first generation type. The performance of the system has been tested using a wooden phantom. The X-ray CT system has shown good imaging capabilities.
引用
收藏
页码:777 / 779
页数:3
相关论文
共 9 条
[1]   Improved performance lead iodide nuclear radiation detectors [J].
Deich, V ;
Roth, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :169-172
[2]   Improved spectrometric characteristics of thallium bromide nuclear radiation detectors [J].
Hitomi, K ;
Murayama, T ;
Shoji, T ;
Suehiro, T ;
Hiratate, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (2-3) :372-378
[3]   Room temperature X- and gamma-ray detectors using thallium bromide crystals [J].
Hitomi, K ;
Muroi, O ;
Shoji, T ;
Suehiro, T ;
Hiratate, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2) :160-164
[4]  
JAZURRAHMAN I, 1987, NUCL INSTRUM METH A, V261, P427, DOI 10.1016/0168-9002(87)90350-0
[5]   CHARGE CARRIER TRANSPORT-PROPERTIES IN THALLIUM BROMIDE CRYSTALS USED AS RADIATION DETECTORS [J].
OLSCHNER, F ;
TOLEDOQUINONES, M ;
SHAH, KS ;
LUND, JC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (03) :1162-1164
[6]   THALLIUM BROMIDE SEMICONDUCTOR X-RAY AND GAMMA-RAY DETECTORS [J].
OLSCHNER, F ;
SHAH, KS ;
LUND, JC ;
ZHANG, J ;
DALEY, K ;
MEDRICK, S ;
SQUILLANTE, MR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) :504-508
[7]  
Rahman I.U., 1984, Phys. Rev. B, V29, P3500
[8]   CHARACTERIZATION OF THALLIUM BROMIDE NUCLEAR-DETECTORS [J].
SHAH, KS ;
OLSCHNER, F ;
MOY, LP ;
LUND, JC ;
SQUILLANTE, MR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 299 (1-3) :57-59
[9]   THALLIUM BROMIDE RADIATION DETECTORS [J].
SHAH, KS ;
LUND, JC ;
OLSCHNER, F ;
MOY, L ;
SQUILLANTE, MR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :199-201