Gestational sac volume: comparison between SonoAVC and VOCAL measurements at 11+0 to 13+6 weeks of gestation

被引:9
作者
Borenstein, M. [1 ]
Azumendi Perez, G. [1 ]
Molina Garcia, F. [1 ]
Romero, M. [1 ]
Anderica, J. R. [1 ]
机构
[1] Ctr Gutenberg, Prenatal Diag Unit, Malaga 29016, Spain
关键词
3D ultrasound; gestational sac; SonoAVC (TM); VOCAL (TM); FLUID-FILLED STRUCTURES; 3-DIMENSIONAL ULTRASOUND; RELIABILITY; VALIDITY;
D O I
10.1002/uog.7342
中图分类号
O42 [声学];
学科分类号
070206 [声学];
摘要
Objectives To assess the novel three-dimensional (3D) tool, Sonography-based Automated Volume Count (TM) (SonoAVC) in the calculation of gestational sac volume at 11 + 0 to 13 + 6 weeks of gestation, to correlate the measurements with those obtained using Virtual Organ Computed-aided AnaLysis (TM) (VOCAL) and to study the reproducibility of SonoAVC volume calculation of this irregularly shaped structure. Methods We acquired 3D volumes of the uterus in 65 pregnancies at 11+ 0 to 13 + 6 weeks of gestation. We performed volume calculation of the gestational sac, excluding the fetus and the placenta, using VOCAL with 15 degrees 12-step rotation. We then repeated the calculation with three different SonoAVC settings and compared both techniques. In 30 cases we assessed the reproducibility of the SonoAVC volume calculations. Results In 95% of cases it was possible to calculate the gestational sac volume with SonoAVC. This volume increased with advancing gestation and the volumes were expressed as delta values to compare the measurements made with VOCAL and the three different SonoAVC settings. There was no difference between delta values of gestational sac volume calculated using VOCAL, and SonoAVC with high and medium growth settings. Reproducibility analysis showed good results. Conclusion Gestational sac volume calculation is feasible with SonoAVC in most cases and does not differ from that performed using VOCAL. High and medium growth SonoAVC settings seem to be more accurate for gestational sac volume calculation, although larger studies are required for standardization of the technique. The reproducibility analysis showed similar results to those previously published. Copyright (C) 2009 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:510 / 514
页数:5
相关论文
共 13 条
[1]
Applying the right statistics: analyses of measurement studies [J].
Bland, JM ;
Altman, DG .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) :85-93
[2]
Reproducibility of fetal renal pelvis volume measurement using three-dimensional ultrasound [J].
Duin, L. K. ;
Willekes, C. ;
Vossen, M. ;
Beckers, M. ;
Offermans, J. ;
Nijhuis, J. G. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (06) :657-661
[3]
Gestational sac volume measured by three-dimensional ultrasound at 11 to 13+6 weeks of gestation: relation to chromosomal defects [J].
Falcon, O ;
Wegrzyn, P ;
Faro, C ;
Peralta, CFA ;
Nicolaides, KH .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 25 (06) :546-550
[4]
Fetal trunk and head volume measured by three-dimensional ultrasound at 11+0 to 13+6 weeks of gestation in chromosomally normal pregnancies [J].
Falcon, O ;
Peralta, CFA ;
Cavoretto, P ;
Faiola, S ;
Nicolaides, KH .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 26 (03) :263-266
[5]
The reliability and validity of three dimensional ultrasound volumetric measurements using an in vitro balloon and in vivo uterine model [J].
Farrell, T ;
Leslie, JR ;
Chien, PFW ;
Agustsson, P .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2001, 108 (06) :573-582
[6]
The use of inversion mode and 3D manual segmentation in volume measurement of fetal fluid-filled structures:: comparison with Virtual Organ Computer-aided AnaLysis (VOCAL™) [J].
Kusanovic, J. P. ;
Nien, J. K. ;
Goncalves, L. F. ;
Espinoza, J. ;
Lee, W. ;
Balasubramaniam, M. ;
Soto, E. ;
Erez, O. ;
Romero, R. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (02) :177-186
[7]
Quantitative and morphological assessment of early gestational sacs using three-dimensional ultrasonography [J].
Lee, W. ;
Deter, R. L. ;
McNie, B. ;
Powell, M. ;
Balasubramaniam, M. ;
Goncalves, L. F. ;
Espinoza, J. ;
Romero, R. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 28 (03) :255-260
[8]
Lung and heart volumes by three-dimensional ultrasound in normal fetuses at 12-32 weeks' gestation [J].
Peralta, CFA ;
Cavoretto, P ;
Csapo, B ;
Falcon, O ;
Nicolaides, KH .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 27 (02) :128-133
[9]
SonoAVC: a novel method of automatic volume calculation [J].
Raine-Fenning, N. ;
Jayaprakasan, K. ;
Clewes, J. ;
Joergner, I. ;
Bonaki, S. Dehghani ;
Chamberlain, S. ;
Devlin, L. ;
Priddle, H. ;
Johnson, I. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (06) :691-696
[10]
Automated follicle tracking facilitates standardization and may improve work flow [J].
Raine-Fenning, N. ;
Jayaprakasan, K. ;
Clewes, J. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 30 (07) :1015-1018