Spectral Accuracy of Molecular Ions in an LTQ/Orbitrap Mass Spectrometer and Implications for Elemental Composition Determination

被引:109
作者
Erve, John C. L. [1 ]
Gu, Ming [2 ]
Wang, Yongdong [2 ]
DeMaio, William [1 ]
Talaat, Rasmy E. [1 ]
机构
[1] Wyeth Res, Drug Safety & Metab, Collegeville, PA 19426 USA
[2] Cerno Biosci, Danbury, CT USA
关键词
RESOLUTION; IDENTIFICATION; DISTRIBUTIONS; ABUNDANCES;
D O I
10.1016/j.jasms.2009.07.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In addition to mass accuracy, the ability of a mass spectrometer to faithfully measure the isotopic distribution of an ion, defined as spectral accuracy, is also important. Although time-of-flight mass spectrometers are reported to possess high spectral accuracy capability compared with other mass spectrometers, the Orbitrap has not yet been investigated. Ten natural products (moxidectin, erythromycin, digoxin, rifampicin, amphotericin B, rapamycin, gramicidin S, cyclosporin A, vancomycin, and thiostrepton) ranging in molecular weight from 639 to 1663 Da were measured on an LTQ/Orbitrap mass spectrometer with resolving power settings of 7.5, 15, 30, 60, and 100 K. The difference in the observed profile isotope pattern compared with the theoretical calculation after peak shape calibration, denoted spectral error, was calculated using the program MassWorks (Cerno Bioscience, Danbury, CT, USA). Spectral errors were least at 7.5 K resolving power (<= 3%) but exceeded 10% for some compounds at 100 K. The increasing spectral error observed at higher resolving power for compounds with complex fine structure might be explained by the phenomena of isotopic beat patterns as observed in FTICR. Several compounds with prominent doubly charged ions allowed comparison of spectral accuracies of singly- versus doubly-charged ions. When using spectral error to rank elemental compositions with formula constraints (C0-100H0-200N0-50O0-50Cl0-5S0-5) and a mass tolerance <= 2 parts-per-million, the correct formula was ranked first 35% of the time. However, spectral error considerations eliminated >99% of possible elemental formulas for compounds with molecular weight >900 Da. (J Am Soc Mass Spectrom 2009, 20, 2058-2069) (C) 2009 American Society for Mass Spectrometry
引用
收藏
页码:2058 / 2069
页数:12
相关论文
共 32 条
[1]  
AMIRAV A, 2006, APPL MASS SPECTROMET, P1
[2]  
BOLT HM, 1976, XENOBIOTICA, V6, P21, DOI 10.3109/00498257609151608
[3]   Improved isotopic abundance measurements for high resolution Fourier transform ion cyclotron resonance mass spectra via time-domain data extraction [J].
Bresson, JA ;
Anderson, GA ;
Bruce, JE ;
Smith, RD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (08) :799-804
[4]   Performance optimisation of a new-generation orthogonal-acceleration quadrupole-time-of-flight mass spectrometer [J].
Bristow, Tony ;
Constantine, Jill ;
Harrison, Mark ;
Cavoit, Fabien .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (08) :1213-1222
[5]   Isotope beating effects in the analysis of polymer distributions by Fourier transform mass spectrometry [J].
Easterling, ML ;
Amster, IJ ;
van Rooij, GJ ;
Heeren, RMA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (11) :1074-1082
[6]   Rapid metabolite identification with sub parts-per-million mass accuracy from biological matrices by direct infusion nanoelectrospray ionization after clean-up on a ZipTip and LTQ/Orbitrap mass spectrometry [J].
Erve, John C. L. ;
DeMaio, William ;
Talaat, Rasmy E. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (19) :3015-3026
[7]   APPLICATION OF LINEAR PREDICTION TO FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SIGNALS FOR ACCURATE RELATIVE ION ABUNDANCE MEASUREMENTS [J].
FARRAR, TC ;
ELLING, JW ;
KRAHLING, MD .
ANALYTICAL CHEMISTRY, 1992, 64 (22) :2770-2774
[8]   Automated interpretation of mass spectra of complex mixtures by matching of isotope peak distributions [J].
Fernández-De-Cossio, J ;
Gonzalez, LJ ;
Satomi, Y ;
Betancourt, L ;
Ramos, Y ;
Huerta, V ;
Besada, V ;
Padron, G ;
Minamino, N ;
Takao, T .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (20) :2465-2472
[9]   Quantitation of ion abundances in Fourier transform ion cyclotron resonance mass spectrometry [J].
Goodner, KL ;
Milgram, KE ;
Williams, KR ;
Watson, CH ;
Eyler, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (11) :1204-1212
[10]   Impact of ion cloud densities on the measurement of relative ion abundances in Fourier transform ion cyclotron resonance mass spectrometry: experimental observations of coulombically induced cyclotron radius perturbations and ion cloud dephasing rates [J].
Gordon, EF ;
Muddiman, DC .
JOURNAL OF MASS SPECTROMETRY, 2001, 36 (02) :195-203