Determination of nitrite with the electrocatalytic property to the oxidation of nitrite on thionine modified aligned carbon nanotubes

被引:177
作者
Zhao, Kun
Song, Haiyan
Zhuang, Shuqi
Dai, Liming
He, Pingang
Fang, Yuzhi [1 ]
机构
[1] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
[2] Univ Dayton, Coll Engn, Dept Chem & Mat Engn, Dayton, OH 45469 USA
关键词
thionine; aligned carbon nanotubes; nitrite; modified electrode; electrocatalytic oxidation;
D O I
10.1016/j.elecom.2006.07.001
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A thionine modified aligned carbon nanotubes (ACNTs) electrode was fabricated and was used to electrochemically determine nitrite. The thionine modified ACNTs electrode exhibited enhanced electrocatalytic behavior to the oxidation of nitrite. The electrochemical mechanism of the thionine/ACNTs electrode towards the oxidation of nitrite was discussed. The thionine modified ACNTs electrode exhibited fast response towards nitrite with a detection limit of 1.12 x 10(-6) mol L-1 and a linear range of 3 x 10(-6) - 5 x 10(-4) mol L-1. The proposed method was successfully applied in the detection of nitrite in real samples. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:65 / 70
页数:6
相关论文
共 44 条
[31]   Electrocatalytic oxidation of nitrite at an aluminum electrode modified by a chemically deposited palladium pentacyanonitrosylferrate film [J].
Pournaghi-Azar, MH ;
Dastangoo, H .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 567 (02) :211-218
[32]  
Rocha JRC, 2001, ELECTROANAL, V13, P155, DOI 10.1002/1521-4109(200102)13:2<155::AID-ELAN155>3.0.CO
[33]  
2-F
[34]   Wells-Dawson-derived tetrameric complexes {K28H8[P2W15Ti3O60.5]4} electrochemical behaviour and electrocatalytic reduction of nitrite and of nitric oxide [J].
Ruhlmann, L ;
Genet, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 568 (1-2) :315-321
[35]  
Spataru N, 2001, J ELECTROCHEM SOC, V148, pE112, DOI 10.1149/1.1346611
[36]   Simultaneous determination of nitrite, nitrate, thiocyanate and uric acid in human saliva by capillary zone electrophoresis and its application to the study of daily variations [J].
Tanaka, Y ;
Naruishi, N ;
Fukuya, H ;
Sakata, J ;
Saito, K ;
Wakida, S .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1051 (1-2) :193-197
[37]   Electrochemical and spectral studies on the catalytic oxidation of nitric oxide and nitrite by high-valent manganese porphyrins at an ITO electrode [J].
Trofimova, NS ;
Safronov, AY ;
Ikeda, O .
ELECTROCHIMICA ACTA, 2005, 50 (24) :4637-4644
[38]   Spectrophotometric determination of nitrate and nitrite in water and some fruit samples using column preconcentration [J].
Wang, GF ;
Satake, M ;
Horita, K .
TALANTA, 1998, 46 (04) :671-678
[39]   Carbon nanotube/teflon composite electrochemical sensors and biosensors [J].
Wang, J ;
Musameh, M .
ANALYTICAL CHEMISTRY, 2003, 75 (09) :2075-2079
[40]   Solubilization of carbon nanotubes by Nafion toward the preparation of amperometric biosensors [J].
Wang, J ;
Musameh, M ;
Lin, YH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (09) :2408-2409