Comparison of plateletpheresis concentrates produced with Spectra LRS version 5.1 and LRS Turbo version 7.0 cell separators

被引:12
作者
Perseghin, P
Mascaretti, L
Riva, M
Sciorelli, G
机构
[1] Osped San Gerardo de Tintori, Azienda Osped, Immunohematol & Transfus Dept, Serv Immunoematol & Trasfus, I-20052 Monza, Italy
[2] Osped San Gerardo de Tintori, Apheresis Unit, I-20052 Monza, Italy
[3] Osped San Gerardo de Tintori, HLA Lab, I-20052 Monza, Italy
关键词
D O I
10.1046/j.1537-2995.2000.40070789.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The importance of transfusing WBC-reduced blood components is widely recognized, as it reduces the risk of alloimmunization and transfusion-transmitted CMV infections, The latest generation of cell separators allows the collection of WBC-reduced apheresis platelet concentrates (APCs). MATERIALS AND METHODS: Consecutive APCs (n = 232) were retrospectively evaluated: 163 collected with the Spectra LRS [leukocyte-reduction system] Version 5.1 (Group A) and 69 with the LRS Turbo Version 7.0 (Group B) (both: CODE BCT). Donor peripheral blood count, procedure data, platelet yield, collection efficiency (CE), and residual WBC count in APCs were recorded. RESULTS: The platelet yield was higher in Group B than in Group A: 5.5 +/- 1.4 versus 4.4 +/- 1.1, p<0.0001; residual WBCs were <5 x 10(6) in 99.4 percent of Group A APCs and in 97.1 percent of Group B APCs. CE was higher in Group B than in Group A: 51.4 +/- 8.7 versus 43.6 +/- 6.3, p<0.0001. Moreover, a correlation between predonation platelet count and platelet yield was observed in both groups. A double product (platelet yield >6.0 x 10(11)) was obtained in 28.9 percent of Group B APCs and in 9.2 percent of Group A APCs. CONCLUSIONS: The Spectra LRS Turbo version 7.0 release showed a better CE and resulted in a higher platelet harvest than did the LRS version 5.1. High predonation platelet counts allow a higher platelet yield.
引用
收藏
页码:789 / 793
页数:5
相关论文
共 22 条
[11]   INADEQUATE WHITE CELL-REDUCTION BY BEDSIDE FILTRATION OF RED-CELL CONCENTRATES [J].
LEDENT, E ;
BERLIN, G .
TRANSFUSION, 1994, 34 (09) :765-768
[12]  
McFarland J, 1997, NEW ENGL J MED, V337, P1861
[13]   White cell reduction during plateletpheresis:: a comparison of three blood cell separators [J].
Moog, R ;
Müller, N .
TRANSFUSION, 1999, 39 (06) :572-577
[14]   Platelet transfusion: A dose-response study [J].
Norol, F ;
Bierling, P ;
Roudot-Thoraval, F ;
Le Coeur, FF ;
Rieux, C ;
Lavaux, A ;
Kuentz, M ;
Duedari, N .
BLOOD, 1998, 92 (04) :1448-1453
[15]   SHOULD ALL PLATELET CONCENTRATES ISSUED BY LEUKOCYTE-POOR [J].
REESINK, HW ;
NYDEGGER, UE ;
BRAND, A ;
PIETERSZ, RNI ;
ANDREU, G ;
GMUR, JP ;
MURPHY, S ;
SCHIFFER, CA ;
KICKLER, TS .
VOX SANGUINIS, 1992, 62 (01) :57-64
[16]   Quality and safety of platelet apheresis concentrates produced with a new leukocyte reduction system [J].
Riggert, J ;
Humpe, A ;
Simson, G ;
Köhler, M .
VOX SANGUINIS, 1998, 74 (03) :182-188
[17]   Activation of the contact system by filtration of platelet concentrates with a negatively charged white cell-removal filter and measurement of venous blood bradykinin level in patients who received filtered platelets [J].
Shiba, M ;
Tadokoro, K ;
Sawanobori, M ;
Nakajima, K ;
Suzuki, K ;
Juji, T .
TRANSFUSION, 1997, 37 (05) :457-462
[18]   Optimal conditions for white cell reduction in red cells by filtration at the patient's bedside [J].
Sirchia, G ;
Rebulla, P ;
Sabbioneda, L ;
Garcea, F ;
Greppi, N .
TRANSFUSION, 1996, 36 (04) :322-327
[19]   PREVENTION OF PRIMARY TRANSFUSION-ASSOCIATED CYTOMEGALOVIRUS-INFECTION IN BONE-MARROW TRANSPLANT RECIPIENTS BY THE REMOVAL OF WHITE CELLS FROM BLOOD COMPONENTS WITH HIGH-AFFINITY FILTERS [J].
VANPROOIJEN, HC ;
VISSER, JJ ;
VANOOSTENDORP, WR ;
DEGAST, GCD ;
VERDONCK, LF .
BRITISH JOURNAL OF HAEMATOLOGY, 1994, 87 (01) :144-147
[20]   BEDSIDE FILTRATION OF BLOOD PRODUCTS IN THE PREVENTION OF HLA ALLOIMMUNIZATION - A PROSPECTIVE RANDOMIZED STUDY [J].
WILLIAMSON, LM ;
WIMPERIS, JZ ;
WILLIAMSON, P ;
COPPLESTONE, JA ;
GOOI, HC ;
MORGENSTERN, GR ;
NORFOLK, DR .
BLOOD, 1994, 83 (10) :3028-3035