Charnley wear model for validation of hip simulators - Ball diameter versus polytetrafluoroethylene and polyethylene wear

被引:55
作者
Clarke, IC
Good, V
Anissian, L
Gustafson, A
机构
[1] Howard and Irene Peterson Tribology Laboratory, Loma Linda University Medical Center, Loma Linda, CA
[2] Department of Orthopedics, Loma Linda University, Medical Center, Loma Linda, CA
关键词
hip simulator; wear; head diameter; polyethylene; polytetrafluoroethylene; cup;
D O I
10.1243/0954411971534656
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wear rates of polytetrafluoroethylene (PTFE) and polyethylene cups were compared in 9-channel and 12-channel simulators, using serum lubrication and gravimetric techniques for wear assessment. Cobalt-chromium (CoCr) and alumina ceramic femoral heads in 22-42 mm diameter range were used to validate simulator wear rates against clinical data. This was also the first study of three femoral head sizes evaluated concurrently in a simulator (with three replicate specimens) and also the first report in which any wear experiments were repeated. Fluid absorption artefacts were within +/-1 per cent of wear magnitude for PTFE and +/-8 per cent for polyethylene and were corrected for. Wear rates were linear as a function of test duration. Precision within each set of three cups was within +/-6 per cent. The wear rates from experiments repeated over 15 months were reproducible to within +/-24 per cent. However, the magnitudes of the simulator wear rates were not clinically accurate, the PTFE wear rates (2843 mm(3)/10(6) cycles; 22 mm diameter) were over three times higher than in vine, the polyethylene 30 to 50 per cent on the low side (23 mm(3)/10(6) cycles; 22 mm diameter). Volumetric wear rate increased with respect to size of femoral head and a linearly increasing relationship of 7-8 per cent/mm was evident with respect to femoral head diameter for both PTFE and polyethylene. These data compared well with the clinical data.
引用
收藏
页码:25 / 36
页数:12
相关论文
共 33 条
[11]  
CLARKE IC, 1995, 7 ANN C TECHN SCI SU
[12]  
CLARKE IC, IN PRESS ACTA ORTHOP
[13]  
CLARKE IC, 1995, T 2 COMB ORTH RES SO, P204
[14]  
Clarke IC, 1981, ENG MED, V10, P189
[15]   COMPARATIVE-STUDY OF THE WEAR OF UHMWPE WITH ZIRCONIA CERAMIC AND STAINLESS-STEEL FEMORAL HEADS IN ARTIFICIAL HIP JOINTS [J].
DERBYSHIRE, B ;
FISHER, J ;
DOWSON, D ;
HARDAKER, C ;
BRUMMITT, K .
MEDICAL ENGINEERING & PHYSICS, 1994, 16 (03) :229-236
[16]   AN EVALUATION OF THE PENETRATION OF CERAMIC FEMORAL HEADS INTO POLYETHYLENE ACETABULAR CUPS [J].
DOWSON, D ;
JOBBINS, B ;
SEYEDHARRAF, A .
WEAR, 1993, 162 (pt B) :880-889
[17]  
Duff-barclay B. I., 1966, TOTAL HUMAN HIP JOIN, V181
[18]   LOW WEAR RATE OF UHMWPE AGAINST ZIRCONIA CERAMIC (Y-PSZ) IN COMPARISON TO ALUMINA CERAMIC AND SUS 316L ALLOY [J].
KUMAR, P ;
OKA, M ;
IKEUCHI, K ;
SHIMIZU, K ;
YAMAMURO, T ;
OKUMURA, H ;
KOTOURA, Y .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07) :813-828
[19]   EFFECT OF FEMORAL-HEAD SIZE ON WEAR OF THE POLYETHYLENE ACETABULAR COMPONENT [J].
LIVERMORE, J ;
ILSTRUP, D ;
MORREY, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (04) :518-528
[20]  
MCCOY TH, 1988, ORTHOP CLIN N AM, V19, P467