Cholesterol biosensor based on N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane self-assembled monolayer

被引:98
作者
Arya, Sunil K.
Prusty, Arun K.
Singh, S. P.
Solanki, Pratima R.
Pandey, Manoj K.
Datta, Monika
Malhotra, Bansi D. [1 ]
机构
[1] Natl Phys Lab, Biomol Elect & Conduct Polymer Res Grp, New Delhi 110012, India
[2] Univ Delhi, Dept Chem, Delhi 110007, India
关键词
cholesterol; cholesterol oxidase (ChOx); N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane (AEAPTS); self-assembled monolayer (SAM); electrochemical impedance;
D O I
10.1016/j.ab.2007.01.029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cholesterol oxidase (ChOx) has been covalently immobilized onto two-dimensional self-assembled monolayer (SAM) of N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane (AEAPTS) deposited on the indium-tin oxide (ITO) coated glass plates using N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide and N-hydroxysuccinimide (EDC/NHS) chemistry. These ChOx/AEAPTS/ITO bioelectrodes are characterized using contact angle (CA) measurements, UV-visible spectroscopy, atomic force microscopy (AFM), electrochemical impedance technique, and Fourier transform infrared (FT-IR) technique. The covalently immobilized ChOx-modified AEAPTS bioelectrodes are used for the estimation of cholesterol in solution using UV-visible technique. These cholesterol sensing bioelectrodes show linearity as 50 to 500 mg/dl for cholesterol solution, detection limit as 25 mg/dl, sensitivity as 4.499 x 10(-5) Abs (mg/dl)(-1), K-m value as 58.137 mg/dl (1.5 mM), apparent enzyme activity as 1.81 x 10(-3) U cm(-2), shelf life of approximately 10 weeks, and electrode reusability as 10 times. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:210 / 218
页数:9
相关论文
共 49 条
  • [1] Application of electrochemically prepared polypyrrole-polyvinyl sulphonate films to DNA biosensor
    Arora, K
    Chaubey, A
    Singhal, R
    Singh, RP
    Pandey, MK
    Samanta, SB
    Malhotra, BD
    Chand, S
    [J]. BIOSENSORS & BIOELECTRONICS, 2006, 21 (09) : 1777 - 1783
  • [2] Poly-(3-hexylthiophene) self-assembled monolayer based cholesterol biosensor using surface plasmon resonance technique
    Arya, Sunil K.
    Solanki, Pratima R.
    Singh, S. P.
    Kaneto, K.
    Pandey, Manoj K.
    Datta, Monika
    Malhotra, Bansi D.
    [J]. BIOSENSORS & BIOELECTRONICS, 2007, 22 (11) : 2516 - 2524
  • [3] Application of octadecanethiol self-assembled monolayer to cholesterol biosensor based on surface plasmon resonance technique
    Arya, Sunil K.
    Solanki, Pratima R.
    Singh, Ravindra P.
    Pandey, Manoj K.
    Datta, Monika
    Malhotra, Bansi D.
    [J]. TALANTA, 2006, 69 (04) : 918 - 926
  • [4] Stabilization of immobilized glucose oxidase against thermal inactivation by silanization for biosensor applications
    Babu, VRS
    Kumar, MA
    Karanth, NG
    Thakur, MS
    [J]. BIOSENSORS & BIOELECTRONICS, 2004, 19 (10) : 1337 - 1341
  • [5] Steady-state oxidation of cholesterol catalyzed by cholesterol oxidase in lipid bilayer membranes on platinum electrodes
    Bokoch, MP
    Devadoss, A
    Palencsár, MS
    Burgess, JD
    [J]. ANALYTICA CHIMICA ACTA, 2004, 519 (01) : 47 - 55
  • [6] An electrochemical multienzymatic biosensor for determination of cholesterol
    Bongiovanni, C
    Ferri, T
    Poscia, A
    Varalli, M
    Santucci, R
    Desideri, A
    [J]. BIOELECTROCHEMISTRY, 2001, 54 (01) : 17 - 22
  • [7] Development of a molecular imprinting thick film electrochemical sensor for cholesterol detection
    Chou, LCS
    Liu, CC
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 110 (02) : 204 - 208
  • [8] Covalent attachment of synthetic DNA to self-assembled monolayer films
    Chrisey, LA
    Lee, GU
    OFerrall, CE
    [J]. NUCLEIC ACIDS RESEARCH, 1996, 24 (15) : 3031 - 3039
  • [9] Application of SPR biosensor for medical diagnostics of human hepatitis B virus (hHBV)
    Chung, JW
    Kim, SD
    Bernhardt, R
    Pyun, JC
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 111 : 416 - 422
  • [10] Towards a label-free optical porous silicon DNA sensor
    Di Francia, G
    La Ferrara, V
    Manzo, S
    Chiavarini, S
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 21 (04) : 661 - 665