Mercury-free sono-electroanalytical detection of lead in human blood by use of bismuth-film-modified boron-doped diamond electrodes

被引:82
作者
Kruusma, J
Banks, CE
Compton, RG
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
[2] Univ Tartu, Inst Phys Chem, EE-51013 Tartu, Estonia
关键词
bismuth film; blood; anodic stripping voltammetry; lead; ultrasound;
D O I
10.1007/s00216-004-2639-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report the electroanalytical determination of lead by anodic stripping voltammetry at in-situ-formed, bismuth-film-modified, boron-doped diamond electrodes. Detection limits in 0.1 mol L-1 nitric acid solution of 9.6x10(-8) mol L-1 (0.2 ppb) and 1.1x10(-8) mol L-1 (2.3 ppb) were obtained after 60 and 300 s deposition times, respectively. An acoustically assisted deposition procedure was also investigated and found to result in improved limits of detection of 2.6x10(-8) mol L-1 (5.4 ppb) and 8.5x10(-10) mol L-1 (0.18 ppb) for 60 and 300 s accumulation times, respectively. Furthermore, the sensitivity obtained under quiescent and insonated conditions increased from 5.5 (quiescent) to 76.7 A mol(-1) L (insonated) for 60 s accumulation and from 25.8 (quiescent) to 317.6 A mol(-1) L (insonated) for 300 s accumulation. Investigation of the use of ultrasound with diluted blood revealed detection limits of the order of 10(-8) mol L-1 were achievable with excellent inter- and intra-reproducibility and sensitivity of 411.9 A mol(-1) L . For the first time, electroanalytical detection of lead in diluted blood is shown to be possible by use of insonated in-situ-formed bismuth-film-modified boron-doped diamond electrodes. This method is a rapid, sensitive, and non-toxic means of clinical sensing of lead in whole human blood.
引用
收藏
页码:700 / 706
页数:7
相关论文
共 39 条
[1]  
Albalak R, 2003, ARCH ENVIRON HEALTH, V58, P172
[2]   Cadmium detection via boron-doped diamond electrodes:: surfactant inhibited stripping voltarnmetry [J].
Banks, CE ;
Hyde, ME ;
Tomcík, P ;
Jacobs, R ;
Compton, RG .
TALANTA, 2004, 62 (02) :279-286
[3]   Ultrasonically enhanced voltammetric analysis and applications: An overview [J].
Banks, CE ;
Compton, RG .
ELECTROANALYSIS, 2003, 15 (5-6) :329-346
[4]  
BANKS CE, 2004, IN PRESS PHYS CHEM C
[5]   Electroanalysis at diamond-like and doped-diamond electrodes [J].
Compton, RG ;
Foord, JS ;
Marken, F .
ELECTROANALYSIS, 2003, 15 (17) :1349-1363
[6]   The membrane free sonoelectroanalytical determination of trace levels of lead and cadmium in human saliva [J].
Hardcastle, JL ;
West, CE ;
Compton, RG .
ANALYST, 2002, 127 (11) :1495-1501
[7]   Direct electrochemistry of cytochrome c at nanocrystalline boron-doped diamond [J].
Haymond, S ;
Babcock, GT ;
Swain, GM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (36) :10634-10635
[8]   A study on operational parameters for advanced use of bismuth film electrode in anodic stripping voltammetry [J].
Hocevar, SB ;
Ogorevc, B ;
Wang, J ;
Pihlar, B .
ELECTROANALYSIS, 2002, 14 (24) :1707-1712
[9]   APPLICATION OF POLYMER-COATED GLASSY-CARBON ELECTRODES TO THE DIRECT DETERMINATION OF TRACE-METALS IN BODY-FLUIDS BY ANODIC-STRIPPING VOLTAMMETRY [J].
HOYER, B ;
FLORENCE, TM .
ANALYTICAL CHEMISTRY, 1987, 59 (24) :2839-2842
[10]   An introduction to bismuth film electrode for use in cathodic electrochemical detection [J].
Hutton, EA ;
Ogorevc, B ;
Hocevar, SB ;
Weldon, F ;
Smyth, MR ;
Wang, J .
ELECTROCHEMISTRY COMMUNICATIONS, 2001, 3 (12) :707-711