Optimized image acquisition for breast tomosynthesis in projection and reconstruction space

被引:72
作者
Chawla, Amarpreet S. [1 ,3 ]
Lo, Joseph Y. [1 ,3 ]
Baker, Jay A. [2 ]
Samei, Ehsan [1 ,3 ]
机构
[1] Duke Univ, Dept Radiol, Dept Med Phys, Durham, NC 27705 USA
[2] Duke Univ, Dept Radiol, Duke Adv Imaging Labs, Durham, NC 27705 USA
[3] Duke Univ, Dept Biomed Engn, Duke Adv Imaging Labs, Durham, NC 27705 USA
关键词
optimization; acquisition parameters; ROC; AUC; Hotelling observer; LG CHO; multiprojection imaging; correlation imaging; breast tomosynthesis; decision fusion; DIGITAL TOMOSYNTHESIS; COMPUTER-SIMULATION; OBSERVER; SYSTEM; NOISE; PLATFORM; QUALITY; CANCER;
D O I
10.1118/1.3231814
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Breast tomosynthesis has been an exciting new development in the field of breast imaging. While the diagnostic improvement via tomosynthesis is notable, the full potential of tomosynthesis has not yet been realized. This may be attributed to the dependency of the diagnostic quality of tomosynthesis on multiple variables, each of which needs to be optimized. Those include dose, number of angular projections, and the total angular span of those projections. In this study, the authors investigated the effects of these acquisition parameters on the overall diagnostic image quality of breast tomosynthesis in both the projection and reconstruction space. Five mastectomy specimens were imaged using a prototype tomosynthesis system. 25 angular projections of each specimen were acquired at 6.2 times typical single-view clinical dose level. Images at lower dose levels were then simulated using a noise modification routine. Each projection image was supplemented with 84 simulated 3 mm 3D lesions embedded at the center of 84 nonoverlapping ROIs. The projection images were then reconstructed using a filtered backprojection algorithm at different combinations of acquisition parameters to investigate which of the many possible combinations maximizes the performance. Performance was evaluated in terms of a Laguerre-Gauss channelized Hotelling observer model-based measure of lesion detectability. The analysis was also performed without reconstruction by combining the model results from projection images using Bayesian decision fusion algorithm. The effect of acquisition parameters on projection images and reconstructed slices were then compared to derive an optimization rule for tomosynthesis. The results indicated that projection images yield comparable but higher performance than reconstructed images. Both modes, however, offered similar trends: Performance improved with an increase in the total acquisition dose level and the angular span. Using a constant dose level and angular span, the performance rolled off beyond a certain number of projections, indicating that simply increasing the number of projections in tomosynthesis may not necessarily improve its performance. The best performance for both projection images and tomosynthesis slices was obtained for 15-17 projections spanning an angular arc of similar to 45 degrees the maximum tested in our study, and for an acquisition dose equal to single-view mammography. The optimization framework developed in this framework is applicable to other reconstruction techniques and other multiprojection systems. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3231814]
引用
收藏
页码:4859 / 4869
页数:11
相关论文
共 27 条
[1]   Stabilized estimates of Hotelling-observer detection performance in patient-structured noise [J].
Barrett, HH ;
Abbey, CK ;
Gallas, B ;
Eckstein, M .
IMAGE PERCEPTION: MEDICAL IMAGING 1998, 1998, 3340 :27-43
[2]   OBJECTIVE ASSESSMENT OF IMAGE QUALITY - EFFECTS OF QUANTUM NOISE AND OBJECT VARIABILITY [J].
BARRETT, HH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1990, 7 (07) :1266-1278
[3]   Digital breast tomosynthesis using an amorphous selenium flat panel detector [J].
Bissonnette, M ;
Hansroul, M ;
Masson, E ;
Savard, S ;
Cadieux, S ;
Warmoes, P ;
Gravel, D ;
Agopyan, J ;
Polischuk, B ;
Haerer, W ;
Mertelmeier, T ;
Lo, JY ;
Chen, Y ;
Dobbins, JT ;
Jesneck, JL ;
Singh, S .
Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 :529-540
[4]   Estimation of the noisy component of anatomical backgrounds [J].
Bochud, FO ;
Valley, JF ;
Verdun, FR ;
Hessler, C ;
Schnyder, P .
MEDICAL PHYSICS, 1999, 26 (07) :1365-1370
[5]   Human observer detection experiments with mammograms and power-law noise [J].
Burgess, AE ;
Jacobson, FL ;
Judy, PF .
MEDICAL PHYSICS, 2001, 28 (04) :419-437
[6]  
Chan H.-P., 2008, PROC INT WORKSHOP DI, V9, P279
[7]  
CHAWLA A, 2008, P INT WORKSH DIG MAM, V9, P635
[8]   A mathematical model platform for optimizing a multiprojection breast imaging system [J].
Chawla, Amarpreet S. ;
Samei, Ehsan ;
Saunders, Robert S. ;
Lo, Joseph Y. ;
Baker, Jay A. .
MEDICAL PHYSICS, 2008, 35 (04) :1337-1345
[9]   Towards Optimized Acquisition Scheme for Multiprojection Correlation Imaging of Breast Cancer [J].
Chawla, Amarpreet S. ;
Saunders, Robert S. ;
Singh, Swatee ;
Lo, Joseph Y. ;
Samei, Ehsan .
ACADEMIC RADIOLOGY, 2009, 16 (04) :456-463
[10]   Importance of point-by-point back projection correction for isocentric motion in digital breast tomosynthesis: Relevance to morphology of structures such as microcalcifications [J].
Chen, Ying ;
Lo, Joseph Y. ;
Dobbins, James T., III .
MEDICAL PHYSICS, 2007, 34 (10) :3885-3892