Comparison of a three-peptide separation by capillary electrochromatography, voltage-assisted liquid chromatography and nano-high-performance liquid chromatography

被引:24
作者
Szucs, V [1 ]
Freitag, R [1 ]
机构
[1] Swiss Fed Inst Technol, Fac Basic Sci, Lab Chem Biotechnol, CH-1015 Lausanne, Switzerland
关键词
electrochromatography; voltage-assisted liquid chromatography; angiotensins; methionine enkephalin; peptides;
D O I
10.1016/j.chroma.2004.05.103
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A mixture of three peptides was separated by capillary electrochromatography (CEC), nano-HPLC and voltage-assisted LC. In the latter case the charged analytes migrate through a neutral stationary phase driven by electrophoresis while their interaction with the stationary phase provides the basis for a chromatographic separation. The stationary phases used were poly(glycidyl methacrylate-co-ethylene dimethacrylate)-based monoliths that could be used directly as neutral "Cl"-type columns for voltage-assisted LC and nano-HPLC, while their application in CEC became possible after derivatization of the epoxy groups with ionogenic N-ethylbutylamine functions. The separation of the peptide mixture was possible in all three modes. Highest plate numbers and resolutions were obtained under voltage-assisted conditions. The elution order showed dependencies on the charge density but also on the hydrophobicity of the peptides and was different in the three investigated chromatographic modes. The effect of changes in the ionic strength and the organic solvent content of the mobile phase on the resolution and the migration behavior of the peptides was investigated and showed the expected behavior. Voltage-assisted LC is suggested as an alternative to CEC for the separation of charged analytes by electrochromatography. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:201 / 210
页数:10
相关论文
共 36 条
[1]   Comparative study of capillary electroendosmotic chromatography and electrically assisted gradient nano-liquid chromatography for the separation of peptides [J].
Adam, T ;
Unger, KK .
JOURNAL OF CHROMATOGRAPHY A, 2000, 894 (1-2) :241-251
[2]   Capillary electrochromatography - A high-efficiency micro-separation technique [J].
Dittmann, MM ;
Rozing, GP .
JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) :63-74
[3]   Reversed-phase electrochromatography of proteins on modified continuous beds using normal-flow and counterflow gradients.: Theoretical and practical considerations [J].
Ericson, C ;
Hjertén, S .
ANALYTICAL CHEMISTRY, 1999, 71 (08) :1621-1627
[4]   Preparation of continuous beds for electrochromatography and reversed-phase liquid chromatography of low-molecular-mass compounds [J].
Ericson, C ;
Liao, JL ;
Nakazato, K ;
Hjerten, S .
JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) :33-41
[5]   Comparison of the chromatographic behavior of monolithic capillary columns in capillary electrochromatography and nano-high-performance liquid chromatography [J].
Freitag, R .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (02) :267-273
[6]   Quantitative analysis and synthesis of the electrokinetic mass transport and adsorption mechanisms of a charged adsorbate in capillary electrochromatography systems employing charged adsorbent particles [J].
Grimes, BA ;
Liapis, AI .
JOURNAL OF CHROMATOGRAPHY A, 2001, 919 (01) :157-179
[7]   Capillary columns with in situ formed porous monolithic packing for micro high-performance liquid chromatography and capillary electrochromatography [J].
Gusev, I ;
Huang, X ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) :273-290
[8]   Capillary electrochromatography of proteins and peptides with porous layer open-tubular columns [J].
Huang, X ;
Zhang, J ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 1999, 858 (01) :91-101
[9]   Band dispersion in chromatography - a universal expression for the contribution from the mobile zone [J].
Knox, JH .
JOURNAL OF CHROMATOGRAPHY A, 2002, 960 (1-2) :7-18
[10]   Specific applications of capillary electrochromatography to biopolymers, including proteins, nucleic acids, peptide mapping, antibodies, and so forth [J].
Krull, IS ;
Sebag, A ;
Stevenson, R .
JOURNAL OF CHROMATOGRAPHY A, 2000, 887 (1-2) :137-163