How does signal fade on photo-stimulable storage phosphor imaging plates when scanned with a delay and what is the effect on image quality?

被引:18
作者
Ang, Dan B. [1 ]
Angelopoulos, Christos [1 ]
Katz, Jerald O. [1 ]
机构
[1] UMKC, Sch Dent, Kansas City, MO 64108 USA
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 2006年 / 102卷 / 05期
关键词
D O I
10.1016/j.tripleo.2005.11.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The goals of this in vitro study were to determine the effect of signal fading of DenOptix photo-stimulable storage phosphor imaging plates scanned with a delay and to determine the effect on the diagnostic quality of the image. In addition, we sought to correlate signal fading with image spatial resolution and average pixel intensity values. Study design: Forty-eight images were obtained of a test specimen apparatus and scanned at 6 delayed time intervals: immediately scanned, I hour, 8 hours, 24 hours, 72 hours, and 168 hours. Six general dentists using Vixvvin2000 software performed a measuring task to determine the location of an endodontic file tip and root apex. One-way ANOVA with repeated measures was used to determine the effect of signal fading (delayed scan time) on diagnostic image quality and average pixel intensity value. Results: There was no statistically significant difference in diagnostic image quality resulting from signal fading. No difference was observed in spatial resolution of the images. There was a statistically significant difference in the pixel intensity analysis of an 8-step aluminum wedge between immediate scanning and 24-hour delayed scan time. Conclusion: There was an effect of delayed scanning on the average pixel intensity value. However, there was no effect on image quality and raters' ability to perform a clinical identification task. Proprietary software of the DenOptix digital imaging system demonstrates an excellent ability to process a delayed scan time signal and create an image of diagnostic quality.
引用
收藏
页码:673 / 679
页数:7
相关论文
共 11 条
[1]   Effect of delayed scanning of storage phosphor plates [J].
Akdeniz, BG ;
Gröndahl, HG ;
Kose, T .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2005, 99 (05) :603-607
[2]   Signal-to-noise ratios of 6 intraoral digital sensors [J].
Attaelmanan, AG ;
Borg, E ;
Gröndahl, HG .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2001, 91 (05) :611-615
[3]   On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems [J].
Borg, E ;
Grondahl, HG .
DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (02) :82-88
[4]   Image plate systems differ in physical performance [J].
Borg, E ;
Attaelmanan, A ;
Gröndahl, HG .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2000, 89 (01) :118-124
[5]   Endodontic working length assessment - Comparison of storage phosphor digital imaging and radiographic film [J].
Cederberg, RA ;
Tidwell, E ;
Frederiksen, NL ;
Benson, BW .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1998, 85 (03) :325-328
[6]   Comments on noise and resolution of the DenOptix radiography system [J].
Couture, RA .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2003, 95 (06) :746-751
[7]   Quantitative dental radiography with a new photostimulable phosphor system [J].
Couture, RA ;
Hildebolt, C .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2000, 89 (04) :498-508
[8]  
Hildebolt C F, 2000, Dent Clin North Am, V44, P273
[9]  
KATO H, 1994, SPECIFICATION ACCEPT, P731
[10]   Analysis of digital images acquired using different phosphor storage plates (PSPs) subjected to varying reading times and storage conditions [J].
Martins, MGBQ ;
Neto, FH ;
Whaites, EJ .
DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (03) :186-190