Electroencephalographic recording during transcranial magnetic stimulation in humans and animals

被引:58
作者
Ives, John R.
Rotenberg, Alexander
Poma, Roberto
Thut, Gregor
Pascual-Leone, Alvaro
机构
[1] Univ Western Ontario, London, ON, Canada
[2] London Hlth Sci Ctr, Dept Clin Neurol Sci, London, ON, Canada
[3] Childrens Hosp, Boston, MA 02115 USA
[4] Univ Guelph, Ontario Vet Coll, Dept Clin Studies, Guelph, ON N1G 2W1, Canada
[5] Univ Hosp Geneva, Dept Neurol, Funct Brain Mapping Lab, Geneva, Switzerland
[6] Univ Geneva, Sch Med, Dept Fundamental Neurosci, Geneva, Switzerland
[7] Beth Israel Deaconess Med Ctr, Ctr Noninvas Brain Stimulat, Boston, MA 02215 USA
关键词
electroencephalogram (EEG); transcranial magnetic stimulation (TMS); electrode; human; animal; safety; epilepsy;
D O I
10.1016/j.clinph.2006.04.010
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: We report on the development of an EEG recording system, comprised of electrodes and amplifiers that are compatible with TMS (single and rapid-rate) in both human and animal studies. Methods: We assembled a versatile multi-channel EEG recording system consisting of: (1) two types of electrodes that are safe during TMS or rTMS. (2) Low slew-rate EEG amplifiers that recover within a few milliseconds after the application of TMS pulses. Results: The two electrode types: (a) a conductive-plastic surface electrode with a conductive-silver epoxy coat and (b) a subdermal silver wire electrode (SWE) are compatible to TMS pulses. The amplifiers recover within 30 ms, so that the EEG can be viewed online, essentially without interruption and/or blocking or excessive artifact. Conclusions: Our TMS compatible electrode and EEG recording system allows safe and online viewing/recording of the subject's (human or animal) EEG/EP during experiments or studies involving TMS or rTMS applications. The TMS compatible electrode/amplifier system can be used with any EEG recording instrument. Significance: A simple recording technique coupled with new electrodes permit safe and readable EEG records during TMS in humans and animals. Such online monitoring of the EEG would allow control of TMS/rTMS parameters based on EEG activity. (c) 2006 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1870 / 1875
页数:6
相关论文
共 19 条
[11]  
Poma R, 2005, EPILEPSIA, V46, P333
[12]   THE HEATING OF METAL-ELECTRODES DURING RAPID-RATE MAGNETIC STIMULATION - A POSSIBLE SAFETY HAZARD [J].
ROTH, BJ ;
PASCUALLEONE, A ;
COHEN, LG ;
HALLETT, M .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1992, 85 (02) :116-123
[13]   Evaluation of commercially available electrodes and gels for recording of slow EEG potentials [J].
Tallgren, P ;
Vanhatalo, S ;
Kaila, K ;
Voipio, J .
CLINICAL NEUROPHYSIOLOGY, 2005, 116 (04) :799-806
[14]   A new device and protocol for combining TMS and online recordings of EEG and evoked potentials [J].
Thut, G ;
Ives, JR ;
Kampmann, F ;
Pastor, MA ;
Pascual-Leone, A .
JOURNAL OF NEUROSCIENCE METHODS, 2005, 141 (02) :207-217
[15]   Effects of single-pulse transcranial magnetic stimulation (TMS) on functional brain activity: a combined event-related TMS and evoked potential study [J].
Thut, G ;
Northoff, G ;
Ives, JR ;
Kamitani, Y ;
Pfennig, A ;
Kampmann, F ;
Schomer, DL ;
Pascual-Leone, A .
CLINICAL NEUROPHYSIOLOGY, 2003, 114 (11) :2071-2080
[16]   Differential effects of low-frequency rTMS at the occipital pole on visual-induced alpha de synchronization and visual-evoked potentials [J].
Thut, G ;
Théoret, H ;
Pfennig, A ;
Ives, J ;
Kampmann, F ;
Northoff, G ;
Pascual-Leone, A .
NEUROIMAGE, 2003, 18 (02) :334-347
[17]  
WALSH V, 2003, NEUROCHRONOMETRICS M
[18]   Risk and safety of repetitive transcranial magnetic stimulation: report and suggested guidelines from the international workshop on the safety of repetitive transcranial magnetic stimulation, June 5-7, 1996 [J].
Wassermann, EM .
EVOKED POTENTIALS-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 108 (01) :1-16
[19]   A comparison of subdermal wire electrodes with collodion-applied disk electrodes in long-term EEG recordings in ICU [J].
Young, G. Bryan ;
Ives, John R. ;
Chapman, Martin G. ;
Mirsattari, Seyed M. .
CLINICAL NEUROPHYSIOLOGY, 2006, 117 (06) :1376-1379