Detection of organophosphorus insecticides with immobilized acetylcholinesterase - comparative study of two enzyme sensors

被引:51
作者
Andreescu, S
Avramescu, A
Bala, C
Magearu, V
Marty, JL
机构
[1] Univ Perpignan, Ctr Phytopharm, CNRS, UMR 5054, F-66860 Perpignan, France
[2] Univ Bucharest, Dept Analyt Chem, Fac Chem, Bucharest 703461 1, Romania
关键词
substrates of acetylcholinesterase; tyrosinase; insecticides; inhibition; screen-printed biosensor;
D O I
10.1007/s00216-002-1442-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two-enzyme systems based on acetylcholinesterase (AChE) - a mono-enzyme system based on AChE, with p-aminophenyl acetate as substrate, and a bi-enzyme system based on AChE and tyrosinase, with phenyl acetate as substrate - have been studied for detection of organophosphate insecticides. The analytical performance and detection limits for determination of the pesticides were compared for the two AChE configurations. The enzyme loading, pH, and applied potential of the bi-enzyme system were optimised. When phenyl acetate was used as substrate for AChE activity the phenol generated by enzymatic hydrolysis was determined with a second enzyme, tyrosinase. Amperometric measurements were performed at 100 mV and -150 mV relative to the Ag/AgCl reference electrode for the mono-enzyme and bi-enzyme systems. Screen-printed sensors were used to detect the organophosphorus pesticides paraoxon and chlorpyrifos ethyl oxon; the detection limits achieved with phenyl acetate as substrate were 5.2 x 10(-3) mg L-1 and 0.56 x 10(-3) mg L-1, respectively.
引用
收藏
页码:39 / 45
页数:7
相关论文
共 20 条
  • [11] Improved stability and altered selectivity of tyrosinase based graphite electrodes for detection of phenolic compounds
    Nistor, C
    Emnéus, J
    Gorton, L
    Ciucu, A
    [J]. ANALYTICA CHIMICA ACTA, 1999, 387 (03) : 309 - 326
  • [12] Noguer T, 1999, FIELD ANAL CHEM TECH, V3, P171
  • [13] AMPEROMETRIC BIOSENSOR FOR THE DETERMINATION OF PHENOLIC-COMPOUNDS USING A TYROSINASE GRAPHITE ELECTRODE IN A FLOW-INJECTION SYSTEM
    ORTEGA, F
    DOMINGUEZ, E
    JONSSONPETTERSSON, G
    GORTON, L
    [J]. JOURNAL OF BIOTECHNOLOGY, 1993, 31 (03) : 289 - 300
  • [14] PHENOL OXIDASE-BASED BIOSENSORS AS SELECTIVE DETECTION UNITS IN COLUMN LIQUID-CHROMATOGRAPHY FOR THE DETERMINATION OF PHENOLIC-COMPOUNDS
    ORTEGA, F
    DOMINGUEZ, E
    BURESTEDT, E
    EMNEUS, J
    GORTON, L
    MARKOVARGA, G
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1994, 675 (1-2) : 65 - 78
  • [15] Determination of anticholinesterase pesticides in real samples using a disposable biosensor
    Palchetti, I
    Cagnini, A
    DelCarlo, M
    Coppi, C
    Mascini, M
    Turner, APF
    [J]. ANALYTICA CHIMICA ACTA, 1997, 337 (03) : 315 - 321
  • [16] 4-AMINOPHENYL ACETATE AS A SUBSTRATE FOR AMPEROMETRIC ESTERASE SENSORS
    PARIENTE, F
    HERNANDEZ, L
    LORENZO, E
    [J]. ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) : 399 - 407
  • [17] Perez Pita M. T., 1997, Analytica Chimica Acta, V340, P89
  • [18] Sadik Omowunmi A., 1996, Biosensors and Bioelectronics, V11, pI, DOI 10.1016/0956-5663(96)85936-7
  • [19] Detection of pesticides in the environment using biosensors based on cholinesterases
    Skladal, P
    Fiala, M
    Krejci, J
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1996, 65 (1-4) : 139 - 148
  • [20] Screen-printed tyrosinase-containing electrodes for the biosensing of enzyme inhibitors
    Wang, J
    Nascimento, VB
    Kane, SA
    Rogers, K
    Smyth, MR
    Angnes, L
    [J]. TALANTA, 1996, 43 (11) : 1903 - 1907