Direct detection of renal function markers using microchip CE with pulsed electrochemical detection

被引:43
作者
Garcia, CD [1 ]
Henry, CS [1 ]
机构
[1] Colorado State Univ, Dept Chem, Ft Collins, CO 80523 USA
关键词
D O I
10.1039/b403529a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Creatinine, creatine, and uric acid are three important compounds that are measured in a variety of clinical assays, most notably for renal function. Traditional clinical assays for these compounds have focused on the use of enzymes or chemical reactions. Electrophoretic microchips have the potential to integrate separation power of capillary electrophoresis with devices that are small, portable, and have the speed of conventional sensors. The development of a microchip CE system for the direct detection of creatinine, creatine, and uric acid is presented. The device uses pulsed amperometric detection (PAD) to detect the nitrogen-containing compounds as well as the easily oxidizable uric acid. Baseline separation of creatinine, creatine and uric acid was achieved using 30 mM borate buffer ( pH = 9.4) in less than 200 s. Linear calibration curves were obtained with limits of detection of 80 mM, 250 mM and 270 mM for creatinine, creatine and uric acid respectively. An optimization of the separation conditions and a comparison of PAD with other amperometric detection modes is also shown. Finally, analysis of a real urine sample is presented with validation of creatinine concentrations using a clinical assay kit based on the Jaffe reaction.
引用
收藏
页码:579 / 584
页数:6
相关论文
共 81 条
[41]   PULSED ELECTROCHEMICAL DETECTION AT NOBLE-METAL ELECTRODES IN LIQUID-CHROMATOGRAPHY [J].
JOHNSON, DC ;
LACOURSE, WR .
ELECTROANALYSIS, 1992, 4 (04) :367-380
[42]   PULSED AMPEROMETRIC DETECTION OF CARBOHYDRATES, AMINES AND SULFUR SPECIES IN ION CHROMATOGRAPHY - THE CURRENT STATE OF RESEARCH [J].
JOHNSON, DC ;
DOBBERPUHL, D ;
ROBERTS, R ;
VANDEBERG, P .
JOURNAL OF CHROMATOGRAPHY, 1993, 640 (1-2) :79-96
[43]   Determination of uremic toxins in biofluids: creatinine, creatine, uric acid and xanthines [J].
Kochansky, CJ ;
Strein, TG .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 747 (1-2) :217-227
[44]   Pulsed electrochemical detection of sulfur-containing antibiotics following high performance liquid chromatography [J].
LaCourse, WR ;
Dasenbrock, CO .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (1-2) :239-252
[45]   Pulsed electrochemical detection of nonchromophoric compounds following capillary electrophoresis [J].
LaCourse, WR ;
Owens, GS .
ELECTROPHORESIS, 1996, 17 (02) :310-318
[46]  
Lacourse WR, 2001, ENANTIOMER, V6, P141
[47]  
LaCourse WR, 1997, PULSED ELECTROCHEMIC
[48]   Simple and sensitive electrode design for microchip electrophoresis/electrochemistry [J].
Liu, Y ;
Vickers, JA ;
Henry, CS .
ANALYTICAL CHEMISTRY, 2004, 76 (05) :1513-1517
[49]   EVALUATION OF SERUM CREATININE MEASUREMENT BY THE DIRECT ACIDIFICATION METHOD FOR ERRORS CONTRIBUTED BY NON-CREATININE CHROMOGENS [J].
LOLEKHA, PH ;
TAKSINAMANEE, R .
CLINICA CHIMICA ACTA, 1980, 107 (1-2) :97-104
[50]   Hypertension in chronic renal failure and ESRD: Prevalence, pathophysiology, and outcomes [J].
Mailloux, LU .
SEMINARS IN NEPHROLOGY, 2001, 21 (02) :146-156