MRI phase mapping of temperature distributions induced in food by microwave heating

被引:37
作者
Nott, KP [1 ]
Hall, LD [1 ]
Bows, JR [1 ]
Hale, M [1 ]
Patrick, ML [1 ]
机构
[1] Univ Cambridge, Sch Clin Med, Herchel Smith Lab Med Chem, Cambridge CB2 2PZ, England
关键词
microwave heating; sterilisation; chemical shift;
D O I
10.1016/S0730-725X(99)00103-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A range of temperature-sensitive MRI parameters of water (T-2, T-1, diffusion coefficient, and chemical shift) were evaluated to map in three dimensions the non-uniform temperature distributions induced by microwave heating in both model and real food systems. Phase mapping was found to be the most robust method, and evaluations of possible experimental errors were based on semi-quantitative studies of homogeneous and heterogeneous systems. The MRI protocol provides complementary phase and magnitude data, which are related to the sample temperature and structural heterogeneity, respectively. Used together, they relate the temperature changes to the differential thermal properties of the various components within a heterogeneous sample. The potential applications of this technique to microwave and other forms of heating is discussed. (C) 2000 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:69 / 79
页数:11
相关论文
共 31 条
[21]   3-POINT PHASE-CONTRAST VELOCITY-MEASUREMENTS WITH INCREASED VELOCITY-TO-NOISE RATIO [J].
LEE, AT ;
PIKE, GB ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) :122-126
[22]   BODY-TEMPERATURE MAPPING BY MAGNETIC-RESONANCE-IMAGING [J].
LEWA, CJ ;
DECERTAINES, JD .
SPECTROSCOPY LETTERS, 1994, 27 (10) :1369-1419
[23]   TISSUE TEMPERATURE MONITORING FOR THERMAL INTERVENTIONAL THERAPY - COMPARISON OF T1-WEIGHTED MR SEQUENCES [J].
MATSUMOTO, R ;
MULKERN, RV ;
HUSHEK, SG ;
JOLESZ, FA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (01) :65-70
[24]   MODIFIED SPIN-ECHO METHOD FOR MEASURING NUCLEAR RELAXATION TIMES [J].
MEIBOOM, S ;
GILL, D .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1958, 29 (08) :688-691
[25]   TEMPERATURE-MEASUREMENT DURING MICROWAVE COOKING [J].
MULLIN, J ;
BOWS, J .
FOOD ADDITIVES AND CONTAMINANTS, 1993, 10 (06) :663-672
[26]   A NEW METHOD OF MEASURING STATIC-FIELD DISTRIBUTION USING MODIFIED FOURIER NMR IMAGING [J].
SEKIHARA, K ;
MATSUI, S ;
KOHNO, H .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1985, 18 (03) :224-227
[27]   Phase imaging on a .2-T MR scanner: Application to temperature monitoring during ablation procedures [J].
Sinha, S ;
Oshiro, T ;
Sinha, U ;
Lufkin, R .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (05) :918-928
[28]   SPIN DIFFUSION MEASUREMENTS: SPIN ECHOES IN THE PRESENCE OF A TIME-DEPENDENT FIELD GRADIENT [J].
STEJSKAL, EO ;
TANNER, JE .
JOURNAL OF CHEMICAL PHYSICS, 1965, 42 (01) :288-+
[29]  
Sun X, 1994, J FOOD P ENG, V17, P423
[30]  
Sun X Z, 1993, J FOOD SCI, V68, P168