Antibody-Based Sensors: Principles, Problems and Potential for Detection of Pathogens and Associated Toxins

被引:249
作者
Byrne, Barry [1 ,2 ]
Stack, Edwina [2 ]
Gilmartin, Niamh [2 ,3 ]
O'Kennedy, Richard [1 ,2 ,3 ]
机构
[1] Dublin City Univ, CBAS, Dublin 9, Ireland
[2] Dublin City Univ, NCSR, Dublin 9, Ireland
[3] Dublin City Univ, BDI, Dublin 9, Ireland
来源
SENSORS | 2009年 / 9卷 / 06期
基金
爱尔兰科学基金会;
关键词
pathogen; antibody; biosensor; electrochemical; surface-plasmon resonance; assay development; SURFACE-PLASMON RESONANCE; ESCHERICHIA-COLI O157-H7; REAL-TIME PCR; ADDRESSABLE POTENTIOMETRIC SENSOR; LINKED-IMMUNOSORBENT-ASSAY; BACILLUS-ANTHRACIS SPORES; SELF-ASSEMBLED MONOLAYER; SINGLE-CHAIN ANTIBODIES; LISTERIA-MONOCYTOGENES; RAPID DETECTION;
D O I
10.3390/s90604407
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Antibody-based sensors permit the rapid and sensitive analysis of a range of pathogens and associated toxins. A critical assessment of the implementation of such formats is provided, with reference to their principles, problems and potential for 'on-site' analysis. Particular emphasis is placed on the detection of foodborne bacterial pathogens, such as Escherichia coli and Listeria monocytogenes, and additional examples relating to the monitoring of fungal pathogens, viruses, mycotoxins, marine toxins and parasites are also provided.
引用
收藏
页码:4407 / 4445
页数:39
相关论文
共 184 条
[41]   Surface plasmon resonance analysis of antipolysaccharide antibody specificity:: Responses to meningococcal group C conjugate vaccines and bacteria [J].
García-Ojeda, PA ;
Hardy, S ;
Kozlowski, S ;
Stein, KE ;
Feavers, IM .
INFECTION AND IMMUNITY, 2004, 72 (06) :3451-3460
[42]   Use of a light-addressable potentiometric sensor for the detection of Escherichia coli O157:H7 [J].
Gehring, AG ;
Patterson, DL ;
Tu, SI .
ANALYTICAL BIOCHEMISTRY, 1998, 258 (02) :293-298
[43]   Enzyme-linked immunomagnetic electrochemical detection of Salmonella typhimurium [J].
Gehring, AG ;
Crawford, CG ;
Mazenko, RS ;
VanHouten, LJ ;
Brewster, JD .
JOURNAL OF IMMUNOLOGICAL METHODS, 1996, 195 (1-2) :15-25
[44]   An antibody microarray, in multiwell plate format, for multiplex screening of foodborne pathogenic bacteria and biomolecules [J].
Gehring, Andrew G. ;
Albin, David M. ;
Reed, Sue A. ;
Tu, Shu-I ;
Brewster, Jeffrey D. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (02) :497-506
[45]   Antibody microarray detection of Escherichia coli O157:H7:: Quantification, assay limitations, and capture efficiency [J].
Gehring, Andrew G. ;
Albin, David M. ;
Bhunia, Arun K. ;
Reed, Sue A. ;
Tu, Shu-I ;
Uknalis, Joseph .
ANALYTICAL CHEMISTRY, 2006, 78 (18) :6601-6607
[46]   Detection of Escherichia coli, Salmonella spp., Shigella spp., Yersinia enterocolitica, Vibrio cholerae, and Campylobacter spp. enteropathogens by 3-reaction multiplex polymerase chain reaction [J].
Gomez-Duarte, Oscar G. ;
Bai, Jing ;
Newell, Elizabeth .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2009, 63 (01) :1-9
[47]  
Gracias KS, 2004, CAN J MICROBIOL, V50, P883, DOI [10.1139/w04-080, 10.1139/W04-080]
[48]   Effect of environmental stresses on antibody-based detection of Escherichia coli O157: H7, Salmonella enterica serotype Enteritidis and Listeria monocytogenes [J].
Hahm, B. -K. ;
Bhunia, A. K. .
JOURNAL OF APPLIED MICROBIOLOGY, 2006, 100 (05) :1017-1027
[49]  
Haines J., 1995, BIA J, V2, P31
[50]   Detection of Staphylococcal Enterotoxin B employing a piezoelectric crystal immunosensor [J].
Harteveld, JLN ;
Nieuwenhuizen, MS ;
Wils, ERJ .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (07) :661-667