A porous poly(acrylonitrile-co-acrylic acid) film-based glucose biosensor constructed by electrochemical entrapment

被引:38
作者
Shan, Dan
He, Yuanyuan
Wang, Shanxia
Xue, Huaiguo [1 ]
Zheng, Hao
机构
[1] Yangzhou Univ, Sch Chem & Chem Engn, Yangzhou 225002, Peoples R China
[2] Zhejiang Univ, Dept Chem, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
glucose biosensor; electrochemical entrapment; poly(acrylonitrile-co-acrylic acid); porous film; copolymer;
D O I
10.1016/j.ab.2006.06.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel glucose biosensor was constructed by electrochemical entrapment of glucose oxidase (GOD) into porous poly(acrylonitrile-co-acrylic acid), which was synthesized via radical polymerization of acrylonitrile and acrylic acid. The obtained biosensor showed a better stability and higher sensitivity than the biosensor prepared by simple physical adsorption. Effects of some experimental variables such as immobilization time, enzyme concentration, pH, applied potential, and temperature on the amperometric response of the sensor were investigated. The biosensor exhibited a rapid response to glucose (< 30 s) with a linear range of 5 x 10(-6) to 3 x 10(-3) M and a sensitivity of 6.82 mA M-1 cm(-2). The apparent Michaelis-Menten constant (K-M(app)) was 7.3 mM. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:215 / 221
页数:7
相关论文
共 36 条
[31]   In vivo Recognition of Cyclopentadienyltricarbonylrhenium (CpTR) derivatives [J].
Uehara, T ;
Koike, M ;
Nakata, H ;
Miyamoto, S ;
Motoishi, S ;
Hashimoto, K ;
Oku, N ;
Nakayama, M ;
Arano, Y .
NUCLEAR MEDICINE AND BIOLOGY, 2003, 30 (03) :327-334
[32]   Amperometric hydrogen peroxide biosensor with sol-gel/chitosan network-like film as immobilization matrix [J].
Wang, G ;
Xu, JJ ;
Chen, HY ;
Lu, ZH .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (04) :335-343
[33]  
WEIBEL MK, 1971, J BIOL CHEM, V246, P2734
[34]   Improved selectivity and stability of glucose biosensor based on in situ electropolymerized polyaniline-polyacrylonitrile composite film [J].
Xue, HG ;
Shen, ZQ ;
Li, CM .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (11) :2330-2334
[35]   Covalent immobilization of glucose oxidase on microporous membranes prepared from poly(vinylidene fluoride) with grafted poly(acrylic acid) side chains [J].
Ying, L ;
Kang, ET ;
Neoh, KG .
JOURNAL OF MEMBRANE SCIENCE, 2002, 208 (1-2) :361-374
[36]   A glucose biosensor based on microporous polyacrylonitrile synthesized by single rare-earth catalyst [J].
Zheng, H ;
Xue, HG ;
Zhang, YF ;
Shen, ZQ .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :541-545