MARGINAL ADAPTATION OF THREE DIFFERENT ZIRCONIUM DIOXIDE THREE-UNIT FIXED DENTAL PROSTHESES

被引:101
作者
Att, Wael [1 ]
Komine, Futoshii [2 ]
Gerds, Thomas [3 ]
Strub, Joerg Rudolf [1 ]
机构
[1] Univ Freiburg, Dept Prosthodont, Sch Dent, D-79106 Freiburg, Germany
[2] Nihon Univ, Sch Dent, Dept Fixed Prosthodont, Tokyo 102, Japan
[3] Univ Copenhagen, Dept Biostat, DK-1168 Copenhagen, Denmark
关键词
PARTIAL DENTURES; CERAMIC MATERIALS; FILM THICKNESS; CAD/CAM; FIT; ACCURACY; STRENGTH; FRAMEWORKS; PRECISION; COPINGS;
D O I
10.1016/S0022-3913(09)60047-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Marginal adaptation is important for the long-term success of dental restorations. Data on the marginal discrepancy of zirconia-based fixed dental prostheses made with different computer-aided design/computer-aided manufacturing technology is needed. Purpose. The purpose of this study was to evaluate the marginal adaptation of different zirconia 3-unit fixed dental prostheses at different fabrication stages and after artificial aging. Material and methods. Twenty-four zirconia 3-unit fixed dental prostheses (DCS, Procera, and VITA YZ-Cerec; n=8) were fabricated using different manufacturing systems and conventionally cemented with glass ionomer cement on human teeth. Each group was aged in a masticatory simulator with thermal cycling. The marginal gaps were examined on epoxy replicas for frameworks and for restorations before and after cementation, and after masticatory simulation, at x250 magnification. Marginal adaptation was assessed using geometric means of the marginal gap values with 95% confidence intervals. Differences between the manufacturing systems and the effect of artificial aging were tested using repeated-measures ANOVA and post hoc paired and unpaired t tests with Bonferroni-Holm correction (alpha=.05). Results. The geometric mean (95% confidence limits) marginal gap values (mu m) for frameworks and for restorations before cementation, after cementation, and after masticatory simulation were, respectively: DCS: 86 (80-93), 86 (8390), 86 (78-94), and 84 (79-90); Procera: 82 (74-89), 89 (81-97), 89 (84-95), and 88 (82-94); and VITA YZ-Cerec: 64 (57-72), 67 (61-77), 76 (71-82), and 78 (76-80). The repeated-measures ANOVA showed significant group and stage effects (P<.05). Group VITA YZ-Cerec showed significantly smaller marginal gap values than groups DCS and Procera at framework (P<.05) and before-cementation (P<.05) stages. The VITA YZ-Cerec group showed significantly smaller marginal gap values than the Procera group after cementation (P<.05). The marginal gap values between different stages were not significantly different for all groups (P>.05). Conclusions. The marginal accuracy of zirconia fixed dental prostheses is influenced by manufacturing technique. (J Prosthet Dent 2009;101:239-247)
引用
收藏
页码:239 / 247
页数:9
相关论文
共 45 条
[1]   Accuracy of machine milling and spark erosion with a CAD/CAM system [J].
Andersson, M ;
Carlsson, L ;
Persson, M ;
Bergman, B .
JOURNAL OF PROSTHETIC DENTISTRY, 1996, 76 (02) :187-193
[2]   ZrO2 three-unit fixed partial dentures:: comparison of failure load before and after exposure to a mastication simulator [J].
Att, W. ;
Grigoriadou, M. ;
Strub, J. R. .
JOURNAL OF ORAL REHABILITATION, 2007, 34 (04) :282-290
[3]   Fracture resistance of different zirconium dioxide three-unit all-ceramic fixed partial dentures [J].
Att, Wael ;
Stamouli, Kassiani ;
Gerds, Thomas ;
Strub, Joerg Rudolf .
ACTA ODONTOLOGICA SCANDINAVICA, 2007, 65 (01) :14-21
[4]  
Bindl A, 2007, INT J PERIODONT REST, V27, P567
[5]   Resin-ceramic bonding: a review of the literature [J].
Blatz, MB ;
Sadan, A ;
Kern, M .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 89 (03) :268-274
[6]   MECHANICAL-PROPERTIES AND SHORT-TERM INVIVO EVALUATION OF YTTRIUM-OXIDE-PARTIALLY-STABILIZED ZIRCONIA [J].
CHRISTEL, P ;
MEUNIER, A ;
HELLER, M ;
TORRE, JP ;
PEILLE, CN .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1989, 23 (01) :45-61
[7]   Current ceramic materials and systems with clinical recommendations: A systematic review [J].
Conrad, Heather J. ;
Seong, Wook-Jin ;
Pesun, Gor J. .
JOURNAL OF PROSTHETIC DENTISTRY, 2007, 98 (05) :389-404
[8]   FUNCTIONAL OCCLUSAL FORCES - INVESTIGATION BY TELEMETRY [J].
DEBOEVER, JA ;
MCCALL, WD ;
HOLDEN, S ;
ASH, MM .
JOURNAL OF PROSTHETIC DENTISTRY, 1978, 40 (03) :326-333
[9]   DEVELOPMENT OF AN ARTIFICIAL ORAL ENVIRONMENT FOR THE TESTING OF DENTAL RESTORATIVES - BI-AXIAL FORCE AND MOVEMENT CONTROL [J].
DELONG, R ;
DOUGLAS, WH .
JOURNAL OF DENTAL RESEARCH, 1983, 62 (01) :32-36
[10]   EFFECT OF INVIVO CROWN MARGIN DISCREPANCIES ON PERIODONTAL HEALTH [J].
FELTON, DA ;
KANOY, BE ;
BAYNE, SC ;
WIRTHMAN, GP .
JOURNAL OF PROSTHETIC DENTISTRY, 1991, 65 (03) :357-364