Electrochemical response of ascorbic acid at conducting and electrogenerated polymer modified electrodes for electroanalytical applications:: a review

被引:155
作者
Malinauskas, A [1 ]
Garjonyté, R [1 ]
Mazeikiene, R [1 ]
Jureviciute, I [1 ]
机构
[1] Inst Chem, LT-2600 Vilnius, Lithuania
关键词
ascorbate; electroanalysis; biosensor; polyaniline;
D O I
10.1016/j.talanta.2004.02.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present short review deals with electroanalytical aspects of electrochemical response of ascorbic acid (Vitamin C) at conducting and electrogenerated polymer modified electrodes. Two main topics are considered: (i) electrocatalytic oxidation of ascorbate at conducting polymer modified electrodes, leading to electroanalytical techniques for ascorbate assay, and (ii) retardation of ascorbate penetration through a layer of electrogenerated polymers, leading to permselective coatings and their diverse uses, especially for biosensing devices. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:121 / 129
页数:9
相关论文
共 120 条
[1]   Fabrication of ultra-thin polypyrrole-glucose oxidase film from supporting electrolyte-free monomer solution for potentiometric biosensing of glucose [J].
Adeloju, SB ;
Moline, AN .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (03) :133-139
[2]   POLYPYRROLE-BASED AMPEROMETRIC BIOSENSOR FOR SULFITE DETERMINATION [J].
ADELOJU, SB ;
SHAW, SJ ;
WALLACE, GG .
ELECTROANALYSIS, 1994, 6 (10) :865-870
[3]  
Alfaya RVS, 2000, J BRAZIL CHEM SOC, V11, P281
[4]   Electrocatalytical properties of a potassium hexacyanoferrate (II) modified polypyrrole electrode.: Application to vitamin C determination [J].
Alonso, JG ;
Sánchez, CD ;
García, MLT ;
Barbado, MDV ;
Batanero, PS .
ANALYTICAL LETTERS, 1999, 32 (10) :1961-1980
[5]   Permselective behaviour at overoxidised poly[1-(2-carboxyethyl)pyrrole] films: Dopamine versus ascorbate [J].
Arrigan, DWM .
ANALYTICAL COMMUNICATIONS, 1997, 34 (09) :241-244
[6]   Photometric methods for the determination of vitamin C [J].
Arya, SP ;
Mahajan, M ;
Jain, P .
ANALYTICAL SCIENCES, 1998, 14 (05) :889-895
[7]   Non-spectrophotometric methods for the determination of Vitamin C [J].
Arya, SP ;
Mahajan, M ;
Jain, P .
ANALYTICA CHIMICA ACTA, 2000, 417 (01) :1-14
[8]   ELECTROCHEMISTRY AND DETECTION OF SOME ORGANIC AND BIOLOGICAL MOLECULES AT CONDUCTING POLY(3-METHYLTHIOPHENE) ELECTRODES [J].
ATTA, NF ;
GALAL, A ;
KARAGOZLER, AE ;
RUSSELL, GC ;
ZIMMER, H ;
MARK, HB .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (04) :333-341
[9]   Electrochemistry and detection of some organic and biological molecules at conducting polymer electrodes .3. Evidence of the electrocatalytic effect of the heteroatom of the poly(hetetroarylene) at the electrode/electrolyte interface [J].
Atta, NF ;
Marawi, I ;
Petticrew, KL ;
Zimmer, H ;
Mark, HB ;
Galal, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 408 (1-2) :47-52
[10]  
Bagheri A, 1997, ANAL LETT, V30, P2023, DOI 10.1080/00032719708001718