Electrochemical response of ascorbic acid at conducting and electrogenerated polymer modified electrodes for electroanalytical applications:: a review

被引:154
作者
Malinauskas, A [1 ]
Garjonyté, R [1 ]
Mazeikiene, R [1 ]
Jureviciute, I [1 ]
机构
[1] Inst Chem, LT-2600 Vilnius, Lithuania
关键词
ascorbate; electroanalysis; biosensor; polyaniline;
D O I
10.1016/j.talanta.2004.02.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present short review deals with electroanalytical aspects of electrochemical response of ascorbic acid (Vitamin C) at conducting and electrogenerated polymer modified electrodes. Two main topics are considered: (i) electrocatalytic oxidation of ascorbate at conducting polymer modified electrodes, leading to electroanalytical techniques for ascorbate assay, and (ii) retardation of ascorbate penetration through a layer of electrogenerated polymers, leading to permselective coatings and their diverse uses, especially for biosensing devices. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:121 / 129
页数:9
相关论文
共 120 条
[81]   Amperometric glucose sensors fabricated by electrochemical polymerization of phenols on carbon paste electrodes containing ferrocene as an electron transfer mediator [J].
Nakabayashi, Y ;
Wakuda, M ;
Imai, H .
ANALYTICAL SCIENCES, 1998, 14 (06) :1069-1076
[82]   Development of an amperometric L-ascorbic acid (Vitamin C) sensor based on electropolymerised aniline for pharmaceutical and food analysis [J].
O'Connell, PJ ;
Gormally, C ;
Pravda, M ;
Guilbault, GG .
ANALYTICA CHIMICA ACTA, 2001, 431 (02) :239-247
[83]  
Özden M, 1999, J APPL POLYM SCI, V71, P2141, DOI 10.1002/(SICI)1097-4628(19990328)71:13<2141::AID-APP3>3.0.CO
[84]  
2-Q
[85]   Synthesis and optimization of permselective polymer (polyindoline) film [J].
Ozden, M ;
Ekinci, E ;
Karagozler, AE .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 1998, 2 (06) :427-431
[86]   AN INTERFERENCE-FREE BIOSENSOR BASED ON GLUCOSE-OXIDASE ELECTROCHEMICALLY IMMOBILIZED IN A NONCONDUCTING POLY(PYRROLE) FILM FOR CONTINUOUS SUBCUTANEOUS MONITORING OF GLUCOSE THROUGH MICRODIALYSIS SAMPLING [J].
PALMISANO, F ;
CENTONZE, D ;
GUERRIERI, A ;
ZAMBONIN, PG .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (9-10) :393-399
[87]   ELECTROSYNTHESIZED BILAYER POLYMERIC MEMBRANE FOR EFFECTIVE ELIMINATION OF ELECTROACTIVE INTERFERENTS IN AMPEROMETRIC BIOSENSORS [J].
PALMISANO, F ;
GUERRIERI, A ;
QUINTO, M ;
ZAMBONIN, PG .
ANALYTICAL CHEMISTRY, 1995, 67 (05) :1005-1009
[88]   Simultaneous monitoring of glucose and lactate by an interference and cross-talk free dual electrode amperometric biosensor based on electropolymerized thin films [J].
Palmisano, F ;
Rizzi, R ;
Centonze, D ;
Zambonin, PG .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (9-10) :531-539
[89]   Overoxidized polypyrrole-coated carbon fiber microelectrodes for dopamine measurements with fast-scan cyclic voltammetry [J].
Pihel, K ;
Walker, QD ;
Wightman, RM .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2084-2089
[90]   Peroxidase-glucose oxidase-poly(amphiphilic pyrrole) bioelectrode for selectively mediated amperometric detection of glucose [J].
Popescu, IC ;
Cosnier, S ;
Labbe, P .
ELECTROANALYSIS, 1997, 9 (13) :998-1004