Development of an immunosensor for the detection of vitellogenin using impedance spectroscopy

被引:92
作者
Darain, F
Park, DS
Park, JS
Shim, YB [1 ]
机构
[1] Pusan Natl Univ, Dept Chem, Pusan 609735, South Korea
[2] Pusan Natl Univ, Ctr Innovat Biophys Sensor Technol, Pusan 609735, South Korea
关键词
vitellogenin; immunosensor; impedance; QCM; conducting polymer; reagentless system;
D O I
10.1016/j.bios.2003.11.014
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A simple and direct immunosensor for the determination of carp (Carassius auratus) vitellogenin (Vtg), a female-specific protein, has been proposed based on an antibody-captured conducting polymer-coated electrode. The monoclonal antibody specific to carp (C auratus) Vtg was immobilized by covalent coupling to the carboxylic acid group on the polymer. The antibody immobilization and antibody-antigen interaction have been demonstrated by means of quartz crystal microbalance and impedance spectroscopic techniques. The impedance change occurred at the sensor surface due to the specific immuno-interaction was utilized to determine Vtg. The sensor showed high selectivity and sensitive response to Vtg in a buffered medium without redox probe. Vtg was determined in the linear range from 1.0 to 8.0 mug/l with the standard deviation of +/-0.13 (n = 3) and the detection limit was determined to be 0.42 mug/l. This method was applied to the determination of Vtg in real male and female carp (C auratus) serum samples. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:1245 / 1252
页数:8
相关论文
共 21 条
[11]   Immunosensors - principles and applications to clinical chemistry [J].
Luppa, PB ;
Sokoll, LJ ;
Chan, DW .
CLINICA CHIMICA ACTA, 2001, 314 (1-2) :1-26
[12]  
Macdonald J. R., 1987, IMPEDANCE SPECTROSCO
[13]   XENOPUS-LAEVIS VITELLOGENIN IS A ZINC PROTEIN [J].
MONTORZI, M ;
FALCHUK, KH ;
VALLEE, BL .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1994, 200 (03) :1407-1413
[14]   Gold electrode functionalized by electropolymerization of a cyano N-substituted pyrrole: application to an impedimetric immunosensor [J].
Ouerghi, O ;
Senillou, A ;
Jaffrezic-Renault, N ;
Martelet, C ;
Ben Ouada, H ;
Cosnier, S .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 501 (1-2) :62-69
[15]   Disposable HSA QCM-immunosensor for practical measurement in liquid [J].
Sakti, SP ;
Hauptmann, P ;
Zimmermann, B ;
Bühling, F ;
Ansorge, S .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 78 (1-3) :257-262
[16]   Monitoring antibody-antigen reactions at conducting polymer-based immunosensors using impedance spectroscopy [J].
Sargent, A ;
Sadik, OA .
ELECTROCHIMICA ACTA, 1999, 44 (26) :4667-4675
[17]   Electrochemistry of conductive polymers .22. Electrochemical and spectroelectrochemical studies of polyazulene growth and its characterization [J].
Shim, YB ;
Park, SM .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1997, 144 (09) :3027-3033
[18]   Analysis of the estrogenic activity of sewage treatment works and receiving waters using vitellogenin induction in fish as a biomarker [J].
Solé, M ;
Porte, C ;
Barceló, D .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (09) :518-525
[19]   Piezoelectric quartz crystal based label-free analysis for allergy disease [J].
Su, XD ;
Chew, FT ;
Li, SFY .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12) :629-639
[20]   Quartz crystal biosensor for detection of the African Swine Fever disease [J].
Uttenthaler, E ;
Kösslinger, C ;
Drost, S .
ANALYTICA CHIMICA ACTA, 1998, 362 (01) :91-100