Whole-body voxel phantoms of paediatric patients - UF Series B

被引:62
作者
Lee, Choonik [1 ]
Lee, Choonsik
Williams, Jonathan L.
Bolch, Wesley E.
机构
[1] Univ Florida, Dept Nucl & Radiol Engn, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Radiol, Gainesville, FL 32610 USA
[3] Univ Florida, Dept Biomed Engn, Gainesville, FL 32611 USA
关键词
D O I
10.1088/0031-9155/51/18/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Following the previous development of the head and torso voxel phantoms of paediatric patients for use in medical radiation protection (UF Series A), a set of whole-body voxel phantoms of paediatric patients (9-month male, 4-year female, 8-year female, 11-year male and 14-year male) has been developed through the attachment of arms and legs from segmented CT images of a healthy Korean adult ( UF Series B). Even though partial-body phantoms (head-torso) may be used in a variety of medical dose reconstruction studies where the extremities are out-of-field or receive only very low levels of scatter radiation, whole-body phantoms play important roles in general radiation protection and in nuclear medicine dosimetry. Inclusion of the arms and legs is critical for dosimetry studies of paediatric patients due to the presence of active bone marrow within the extremities of children. While the UF Series A phantoms preserved the body dimensions and organ masses as seen in the original patients who were scanned, comprehensive adjustments were made for the Series B phantoms to better match International Commission on Radiological Protection (ICRP) age-interpolated reference body masses, body heights, sitting heights and internal organ masses. The CT images of arms and legs of a Korean adult were digitally rescaled and attached to each phantom of the UF series. After completion, the resolutions of the phantoms for the 9-month, 4-year, 8-year, 11-year and 14-year were set at 0.86 mm x 0.86 mm x 3.0 mm, 0.90 mm x 0.90 mm x 5.0 mm, 1.16 mm x 1.16 mm x 6.0 mm, 0.94 mm x 0.94 mm x 6.00 mm and 1.18 mm x 1.18 mm x 6.72 mm, respectively.
引用
收藏
页码:4649 / 4661
页数:13
相关论文
共 14 条
[1]  
[Anonymous], 2003, Ann ICRP, V32, P3
[2]   Voxel-based computational models of real human anatomy: a review [J].
Caon, M .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2004, 42 (04) :229-235
[3]  
*ICRP, 1995, ICRP PUBL, V70, P1
[4]  
*ICRU, 1992, 46 ICRU INT COMM RAD
[5]   Tissue-equivalent materials for construction of tomographic dosimetry phantoms in pediatric radiology [J].
Jones, AK ;
Hintenlang, DE ;
Bolch, WE .
MEDICAL PHYSICS, 2003, 30 (08) :2072-2081
[6]   A realistic anthropomorphic phantom for calculating specific absorbed fractions of energy deposited from internal gamma emitters [J].
Jones, DG .
RADIATION PROTECTION DOSIMETRY, 1998, 79 (1-4) :411-414
[7]   Physical phantom of typical Korean male for radiation protection purpose [J].
Kim, JI ;
Choi, H ;
Lee, BI ;
Lim, YK ;
Kim, CS ;
Lee, JK ;
Lee, C .
RADIATION PROTECTION DOSIMETRY, 2006, 118 (01) :131-136
[8]   The UF series of tomographic computational phantoms of pediatric patients [J].
Lee, C ;
Williams, JL ;
Lee, C ;
Bolch, WE .
MEDICAL PHYSICS, 2005, 32 (12) :3537-3548
[9]   Development of the two Korean adult tomographic computational phantoms for organ dosimetry [J].
Lee, C ;
Lee, C ;
Park, SH ;
Lee, JK .
MEDICAL PHYSICS, 2006, 33 (02) :380-390
[10]   Age-dependent organ and effective dose coefficients for external photons: a comparison of stylized and voxel-based paediatric phantoms [J].
Lee, Choonik ;
Lee, Choonsik ;
Bolch, Wesley E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (18) :4663-4688