Biomechanical behavior of MRI-signal-inducing bone cements after vertebroplasty in osteoporotic vertebral bodies: An experimental cadaver study

被引:3
作者
Wichlas, Florian [1 ]
Trzenschik, Heidi [1 ]
Tsitsilonis, Serafim [1 ,2 ]
Rohlmann, Antonius [3 ]
Bail, Hermann-Josef [4 ]
机构
[1] Charite, Ctr Musculoskeletal Surg, D-13353 Berlin, Germany
[2] Charite, Berlin Brandenburg Ctr Regenerat Therapies BSRT, D-13353 Berlin, Germany
[3] Charite, Julius Wolff Inst, D-13353 Berlin, Germany
[4] Nuremberg Hosp South, Clin Traumatol & Orthoped, D-90471 Nurnberg, Germany
关键词
Cementoplasty; Vertebroplasty; MRI-guided surgery; Polymethylmethacrylate cement; Pathologic spinal fractures; Stiffness; PERCUTANEOUS VERTEBROPLASTY; HYDROXYAPATITE CEMENT; POLYMETHYLMETHACRYLATE CEMENTS; PMMA CEMENT; AUGMENTATION; VOLUME; FRACTURES; STIFFNESS; STRENGTH; KYPHOPLASTY;
D O I
10.1016/j.clinbiomech.2014.03.002
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Background: Conventional water-free polymethylmethacrylate cements are not MRI visible due to the lack of free protons. A new MRI-visible bone cement was developed through the addition of a contrast agent and either a saline solution or a hydroxyapatite (Wichlas et al., 2010). The purposes of the study were to examine the influence of the two MRI-signal-inducing cements on the biomechanical behavior of cadaveric osteoporotic vertebral bodies after vertebroplasty and to compare the performance of the cements with conventional polymethylmethacrylate cement Methods: Three different cements were used: standard polymethylmethacrylate cement and two modified MRI-signal-inducing cements that were mixed with either a 0.9% saline solution or a hydroxyapatite. The modulus of elasticity for the standard polymethylmethacrylate cement was 2040 MPa, and the moduli for the MET-signal-inducing cements that were mixed with a 0.9% saline solution and a hydroxyapatite were 1477 and 1225 MPa, respectively. The lumbar vertebral bodies from nine osteoporotic spines (mean age = 87 years, range = 78 99 years) of female cadavers were examined. Three groups were formed: polymethylmethacrylate cement with saline solution (n = 14), polymethylmethacrylate cement with hydroxyapatite (n = 12) and polymethylmethacrylate cement (n = 13). The vertebral bodies were biomechanically tested before and after vertebroplasty. Stiffness was chosen as the primary biomechanical parameter. Findings: The vertebral body stiffness was nearly two-fold greater after vertebroplasty, and this increase was statistically significant for every group. All the groups had similar vertebral body stiffness value before and after the vertebroplasty. The UNIANOVA test for multivariate analysis of variance showed no influence of lumbar level, injected cement volume and initial vertebral body stiffness. Interpretation: The elastic moduli of the cements appear to exert little influence on the biomechanical values when the cement is in the vertebral body. Based on the direct comparison with the classic polymethylmethacrylate cement, we believe that the implementation of such cements for MET-guided vertebroplasties is feasible. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:571 / 576
页数:6
相关论文
共 37 条
[1]
ALEXEEVA L, 1994, WHO TECH REP SER, V843, P1
[2]
Filler materials for augmentation of osteoporotic vertebral fractures [J].
Arabmotlagh, M. ;
Rauschmann, M. .
ORTHOPADE, 2010, 39 (07) :687-692
[3]
The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures [J].
Bai, B ;
Jazrawi, LM ;
Kummer, FJ ;
Spivak, JM .
SPINE, 1999, 24 (15) :1521-1526
[4]
Signal-inducing bone cements for MRI-guided spinal cementoplasty: evaluation of contrast-agent-based polymethylmethacrylate cements [J].
Bail, Hermann Josef ;
Sattig, Christoph ;
Tsitsilonis, Serafim ;
Papanikolaou, Ioannis ;
Teichgraeber, Ulf Karl Mart ;
Wichlas, Florian .
SKELETAL RADIOLOGY, 2012, 41 (06) :651-657
[5]
Biomechanical impact of vertebroplasty - Postoperative biomechanics of vertebroplasty [J].
Baroud, G ;
Bohner, M .
JOINT BONE SPINE, 2006, 73 (02) :144-150
[6]
Intraoperative Position Determination of Bone Cement Trocars by 3-dimensional Imaging in Patients With Osteoporotic Vertebral Fractures [J].
Beck, Markus ;
Mittlmeier, Thomas ;
Gierer, Philip ;
Harms, Christoph ;
Rotter, Robert ;
Gradl, Georg .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2010, 23 (07) :E16-E23
[7]
The biomechanics of vertebroplasty - The effect of cement volume on mechanical behavior [J].
Belkoff, SM ;
Mathis, JM ;
Jasper, LE ;
Deramond, H .
SPINE, 2001, 26 (14) :1537-1541
[8]
An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Jasper, LE ;
Deramond, H .
SPINE, 2001, 26 (14) :1542-1546
[9]
Biomechanical evaluation of a new bone cement for use in vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Erbe, EM ;
Fenton, DC .
SPINE, 2000, 25 (09) :1061-1064
[10]
Belkoff SM, 2002, AM J NEURORADIOL, V23, P1647