Biomechanical impact of vertebroplasty - Postoperative biomechanics of vertebroplasty

被引:68
作者
Baroud, G [1 ]
Bohner, M
机构
[1] Univ Sherbrooke, Dept Mech Engn, Biomech Lab, Sherbrooke, PQ J1K 2R1, Canada
[2] Dr Hc Robert Mathys Fdn, Bettlach, Switzerland
基金
加拿大健康研究院;
关键词
vertebroplasty; polymethylmethacrylate; adjacent fractures; biomechanics;
D O I
10.1016/j.jbspin.2005.02.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. - To examine the biornechanisms underlying adjacent fractures following vertebroplasty, an emerging procedure to stabilize fractured vertebrae. In this procedure, bone cement is injected percutaneously into the vertebral cancellous bone. Once hardened, the cement offers mechanical reinforcement to the weakened vertebra. Recent clinical and biomechanical reports suggest that this procedure may cause new fractures adjacent to the one augmented. The cause and extend is unclear yet. The focus here is on the biomechanical hypothesis resulting from the rigid cement augmentation. Methods. - A combination of experimental and numerical studies, in additional to a review of recent clinical reports. Results. -The broader finding suggests that vertebroplasty changes the mechanical loading in adjacent vertebrae. Specifically, an increase in adjacent loading in the range of 17% has been found. The mechanism underlying this increase seemed to stem from the excessive cement rigidity that reduced the endplate bulge of the augmented vertebra, thereby reducing the local spinal joint flexibility. The reduction in joint flexibility seeks to reverse itself by creating an increase in the inter-vertebral disc pressure. The increased disc pressure seeks to relieve itself by increasing the load on the adjacent vertebra. The increased load on the adjacent vertebra relates directly to an increased risk of fracture. Conclusions. - Although an increasing amount of evidence exists to support this theory of the origin of adjacent fractures, one must be cautious. Vertebroplasty is a relatively new procedure and further observations and, ultimately, prospective clinical studies are required to conclusively determine the cause and extend of adjacent fractures. (c) 2005 Elsevier SAS. All rights reserved.
引用
收藏
页码:144 / 150
页数:7
相关论文
共 62 条
[1]  
ANANTHAKRISHNAN D, 2003, ANN M AM AC ORTH SUR, P472
[2]   Influence of mixing method on the cement temperature-mixing time history and doughing time of three acrylic cements for vertebroplasty [J].
Baroud, G ;
Samara, M ;
Steffen, T .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2004, 68B (01) :112-116
[3]   Biomechanical explanation of adjacent fractures following vertebroplasty [J].
Baroud, G ;
Heini, P ;
Nemes, J ;
Bohner, M ;
Ferguson, S ;
Steffen, T .
RADIOLOGY, 2003, 229 (02) :606-607
[4]  
Baroud G., 2003, Computer Methods in Biomechanics and Biomedical Engineering, V6, P133, DOI 10.1080/1025584031000095746
[5]   Load shift of the intervertebral disc after a vertebroplasty: a finite-element study [J].
Baroud, G ;
Nemes, J ;
Heini, P ;
Steffen, T .
EUROPEAN SPINE JOURNAL, 2003, 12 (04) :421-426
[6]   Percutaneous vertebroplasty for pain relief and spinal stabilization [J].
Barr, JD ;
Barr, MS ;
Lemley, TJ ;
McCann, RM .
SPINE, 2000, 25 (08) :923-928
[7]   The biomechanics of vertebroplasty - The effect of cement volume on mechanical behavior [J].
Belkoff, SM ;
Mathis, JM ;
Jasper, LE ;
Deramond, H .
SPINE, 2001, 26 (14) :1537-1541
[8]   Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty [J].
Belkoff, SM ;
Molloy, S .
SPINE, 2003, 28 (14) :1555-1559
[9]  
Belkoff SM, 2002, AM J NEURORADIOL, V23, P1647
[10]   Adjacent vertebral failure after vertebroplasty - A biomechanical investigation [J].
Berlemann, U ;
Ferguson, SJ ;
Nolte, LP ;
Hein, PF .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (05) :748-752