Construction of amperometric immunosensors based on the electrogeneration of a permeable biotinylated polypyrrole film

被引:65
作者
Ionescu, RE
Gondran, C
Gheber, LA
Cosnier, S
Marks, RS
机构
[1] Ben Gurion Univ Negev, Inst Appl Biosci, IL-84105 Beer Sheva, Israel
[2] Ben Gurion Univ Negev, Dept Biotechnol Engn, IL-84105 Beer Sheva, Israel
[3] Univ Grenoble 1, FR CNRS 2607, Inst Chim Mol Grenoble, UMR CNRS 5630,Lab Electrochim Organ & Photochim R, Grenoble, France
关键词
D O I
10.1021/ac049413z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction of amperometric immunosensors to cholera antitoxin immunoglobulins were shown to have improved sensitivity when the cholera toxin B subunit biorecognition entity was linked to an electrogenerated biotinylated polypyrrole film copolymerized with pyrrolelactobionamide monomer. The copolymer exhibits greater film permeability than biotinylated polypyrrolic or polyphenolic films for the permeation of electroactive species. Hence, when the presence of the HRP marker of the immunoassay was determined using hydroquinone, the production of electroactive quinone was shown to permeate faster to the electrode, thus providing a faster response time.
引用
收藏
页码:6808 / 6813
页数:6
相关论文
共 47 条
[1]   Validation of antibody-based recognition by piezoelectric transducers through electroacoustic admittance analysis [J].
Bizet, K ;
Gabrielli, C ;
Perrot, H ;
Therasse, J .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4) :259-269
[2]   Poly(pyrrole-biotin): a new polymer for biomolecule grafting on electrode surfaces [J].
Cosnier, S ;
Lepellec, A .
ELECTROCHIMICA ACTA, 1999, 44 (11) :1833-1836
[3]   Enhancement of biosensor sensitivity in aqueous and organic solvents using a combination of poly(pyrrole-ammonium) and poly(pyrrole-lactobionamide) films as host matrices. [J].
Cosnier, S ;
Lepellec, A ;
Guidetti, B ;
Rico-Lattes, I .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 449 (1-2) :165-171
[4]  
Cosnier S, 1998, ELECTROANAL, V10, P808, DOI 10.1002/(SICI)1521-4109(199809)10:12<808::AID-ELAN808>3.3.CO
[5]  
2-B
[6]   A biotinylated conducting polypyrrole for the spatially controlled construction of an amperometric biosensor [J].
Cosnier, S ;
Stoytcheva, M ;
Senillou, A ;
Perrot, H ;
Furriel, RPM ;
Leone, FA .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3692-3697
[7]   Biosensors based on electropolymerized films: new trends [J].
Cosnier, S .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (03) :507-520
[8]   Reagentless amperometric immunosensors based on direct electrochemistry of horseradish peroxidase for determination of carcinoma antigen-125 [J].
Dai, Z ;
Yan, F ;
Chen, J ;
Ju, HX .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5429-5434
[9]   INCORPORATION OF ANIONIC COBALT PORPHYRIN BY ANION-EXCHANGE INTO POLYPYRROLE FILMS CONTAINING ALKYLAMMONIUM GROUPS [J].
DEGREGORI, I ;
CARRIER, M ;
DERONZIER, A ;
MOUTET, JC ;
BEDIOUI, F ;
DEVYNCK, J .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1992, 88 (11) :1567-1572
[10]   Reversible oligonucleotide immobilisation based on biotinylated polypyrrole film [J].
Dupont-Filliard, A ;
Roget, A ;
Livache, T ;
Billon, M .
ANALYTICA CHIMICA ACTA, 2001, 449 (1-2) :45-50