Quinohemoprotein alcohol dehydrogenase-based reagentless amperometric biosensor for ethanol monitoring during wine fermentation

被引:75
作者
Niculescu, M
Erichsen, T
Sukharev, V
Kerenyi, Z
Csöregi, E
Schuhmann, W
机构
[1] Lund Univ, Dept Biotechnol, S-22100 Lund, Sweden
[2] Ruhr Univ Bochum, D-44780 Bochum, Germany
[3] Moscow MV Lomonosov State Univ, Dept Chem, RU-119899 Moscow, Russia
[4] Minist Agr, Res Inst Viticulture & Enol, H-6001 Kecskemet, Hungary
关键词
alcohol dehydrogenase; ethanol; biosensor; fermentation; on-line process control; redox polymer; sequential-injection analysis;
D O I
10.1016/S0003-2670(02)00344-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the development and optimization of an amperometric biosensor for monitoring ethanol in beverages. The biosensor is constructed by cross-linking a quinoprotein alcohol dehydrogenase (QH-ADH) to an Os-complex-modified poly(vinylimidazole) redox polymer using poly(ethylene glycol) diglycidyl ether. The optimum biosensor configuration was evaluated by changing the ratio between enzyme, redox polymer, and cross-linker using conventional graphite rods as basis electrodes. The optimized sensor showed a sensitivity of 0.336+/-0.025 A M-1 cm(2) for ethanol and a detection limit (calculated as three times the signal-to-noise ratio) of 1 muM. This biosensor configuration was further evaluated in a conventional flow-injection system and the applicability for the determination of ethanol in diverse wine samples could be successfully demonstrated. Adaptation of this sensor configuration to screen-printed (SP) electrodes allowed their integration into an automated sequential-injection analyzer and the successful on-line monitoring of ethanol during wine fermentation processes. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:39 / 51
页数:13
相关论文
共 25 条
  • [21] DEVELOPMENT OF AN EXTREMELY FLEXIBLE AUTOMATIC ANALYZER WITH INTEGRATED BIOSENSORS FOR ONLINE CONTROL OF FERMENTATION PROCESSES
    SCHUHMANN, W
    WOHLSCHLAGER, H
    HUBER, J
    SCHMIDT, HL
    STADLER, H
    [J]. ANALYTICA CHIMICA ACTA, 1995, 315 (1-2) : 113 - 122
  • [22] Electron-transfer pathways between redox enzymes and electrode surfaces:: Reagentless biosensors based on thiol-monolayer-bound and polypyrrole-entrapped enzymes
    Schuhmann, W
    Zimmermann, H
    Habermüller, KV
    Laurinavicius, V
    [J]. FARADAY DISCUSSIONS, 2000, 116 : 245 - 255
  • [23] A disposable reagentless screen-printed amperometric biosensor for the measurement of alcohol in beverages
    Sprules, SD
    Hartley, IC
    Wedge, R
    Hart, JP
    Pittson, R
    [J]. ANALYTICA CHIMICA ACTA, 1996, 329 (03) : 215 - 221
  • [24] Alcohol biosensors based on coupled oxidase-peroxidase systems
    Vijayakumar, AR
    Csoregi, E
    Heller, A
    Gorton, L
    [J]. ANALYTICA CHIMICA ACTA, 1996, 327 (03) : 223 - 234
  • [25] FLOW-INJECTION DETERMINATION OF ETHANOL BY FIBEROPTIC CHEMILUMINESCENCE MEASUREMENT
    XIE, XF
    SULEIMAN, AA
    GUILBAULT, GG
    YANG, ZM
    SUN, ZA
    [J]. ANALYTICA CHIMICA ACTA, 1992, 266 (02) : 325 - 329