A solid-state electrochemiluminescence biosensing switch for detection of thrombin based on ferrocene-labeled molecular beacon aptamer

被引:108
作者
Wang, Xiaoying [1 ]
Dong, Ping [2 ]
Yun, Wen [2 ]
Xu, Ying [2 ]
He, Pingang [2 ]
Fang, Yuzhi [2 ]
机构
[1] Southeast Univ, Sch Publ Hlth, Nanjing 210009, Peoples R China
[2] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
关键词
Solid-state electrochemiluminescence biosensing switch; Molecular beacon aptamer; Thrombin; Ferrocene; Quenching effect; SENSITIVE DNA DETECTION; ELECTROGENERATED CHEMILUMINESCENCE; ELECTROCHEMICAL DETECTION; COMPOSITE FILMS; RU(BPY)(3)(2+); HYBRIDIZATION; PROTEIN; PROBES; GOLD; NANOPARTICLES;
D O I
10.1016/j.bios.2009.04.019
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A solid-state electrochemiluminescence (ECL) biosensing switch system based on special ferrocene-labeled molecular beacon aptamer (Fc-MBA) has been developed successfully for thrombin detections. Such special switch system includes two main parts, an ECL substrate and an ECL intensity switch. The ECL substrate was made by modifying the complex of Au nanoparticle and Ruthenium (II) tris-(bipyridine) (Ru(bpy)(3)(2+)-AuNPs) onto Au electrode. A molecular beacon aptamer labeled by ferrocene acted as the ECL intensity switch. The loop bases of the ECL intensity switch are designed with special anti-thrombin aptamer sequence which could be combined with its target protein via the reaction between aptamer and thrombin. During the reactions, the molecular beacon aptamer opened its stem-loop, and the labeled Fc was consequently kept away from the ECL substrate. Such structural change resulted in an obvious ECL intensity increment due to the decreased quenching effect of Fc to the ECL substrate. The analytic results are sensitive and specific. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3288 / 3292
页数:5
相关论文
共 45 条
[21]   Molecular aptamer beacons for real-time protein recognition [J].
Li, JWJ ;
Fang, XH ;
Tan, WH .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2002, 292 (01) :31-40
[22]   Electrogenerated chemiluminescence aptamer-based method for the determination of thrombin incorporating quenching of tris(2,2′-bipyridine)ruthenium by ferrocene [J].
Li, Yan ;
Qi, Honglan ;
Peng, Yage ;
Gao, Qiang ;
Zhang, Chengxiao .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (09) :1322-1325
[23]   Determination of carbamates in nature water based on the enhancement of electrochemiluminescent of Ru(bpy)32+ at the multi-wall carbon nanotube-moditied electrode [J].
Lin, Zhenyu ;
Chen, Guonan .
TALANTA, 2006, 70 (01) :111-115
[24]   New trends in affinity sensing: aptamers for ligand binding [J].
Luzi, E ;
Minunni, M ;
Tombelli, S ;
Mascini, M .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (11) :810-818
[25]   Hairpin-DNA probe for enzyme-amplified electrochemical detection of Legionella pneumophila [J].
Miranda-Castro, Rebeca ;
de-los-Santos-Alvarez, Patricia ;
Lobo-Castanon, M. Jesus ;
Miranda-Ordieres, Arturo J. ;
Tunon-Blanco, Paulino .
ANALYTICAL CHEMISTRY, 2007, 79 (11) :4050-4055
[26]   Applications of Nanomaterials in Electrogenerated Chemiluminescence Biosensors [J].
Qi, Honglan ;
Peng, Yage ;
Gao, Qiang ;
Zhang, Chengxiao .
SENSORS, 2009, 9 (01) :674-695
[27]   Reagentless, reusable, ultrasensitive electrochemical molecular beacon aptasensor [J].
Radi, AE ;
Sánchez, JLA ;
Baldrich, E ;
O'Sullivan, CK .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (01) :117-124
[28]   Hybridization of single-stranded DNA targets to immobilized complementary DNA probes: comparison of hairpin versus linear capture probes [J].
Riccelli, PV ;
Merante, F ;
Leung, KT ;
Bortolin, S ;
Zastawny, RL ;
Janeczko, R ;
Benight, AS .
NUCLEIC ACIDS RESEARCH, 2001, 29 (04) :996-1004
[29]   Electrochemiluminescence (ECL) [J].
Richter, MM .
CHEMICAL REVIEWS, 2004, 104 (06) :3003-3036
[30]   A PLAYER OF MANY PARTS - THE SPOTLIGHT FALLS ON THROMBINS STRUCTURE [J].
STUBBS, MT ;
BODE, W .
THROMBOSIS RESEARCH, 1993, 69 (01) :1-58