Concurrent validity of a trunk tri-axial accelerometer system for gait analysis in older adults

被引:111
作者
Hartmann, Antonia [1 ]
Luzi, Susanna [1 ]
Murer, Kurt [1 ]
de Bie, Rob A. [2 ]
de Bruin, Eling D. [1 ]
机构
[1] ETH Honggerberg, HIT Gebaude, Inst Human Movement Sci & Sport, CH-8093 Zurich, Switzerland
[2] Maastricht Univ, Care & Publ Hlth Res Inst, Dept Epidemiol, NL-6200 MD Maastricht, Netherlands
关键词
Accelerometry; Validity; Gait; Aging; GAITRITE(R) WALKWAY SYSTEM; TEST-RETEST RELIABILITY; HUMAN WALKING; PARAMETERS; QUANTIFICATION; VARIABILITY; PEOPLE;
D O I
10.1016/j.gaitpost.2008.11.003
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The aim of this study was (1) to determine the concurrent validity of a trunk tri-axial accelerometer system (DynaPort (R)(MiniMod)) with the GAITRite (R) system for spatio-temporal gait parameters at preferred, slow and fast self-selected walking speed that were recorded for averaged and individual step data in an older adult population and (2) to compare the levels of agreement for averaged step data from different walking distances and individual step data. The levels of agreement between the two systems for averaged step data was excellent for walking speed, cadence, step duration and step length (intraclass correlation coefficients (ICCs) between 0.99 and 1.00, ratios limits of agreement (RLOA) between 0.7% and 3.3%), moderate for variability of step duration (ICCs between 0.88 and 0.98 and RLOAs between 19% and 34%) and low for variability of step length (ICCs between 0.24 and 0.33 and RLOAs between 73% and 87%). The levels of agreement for individual step duration and step length were moderate with ICCs between 0.81 and 0.89 and with RLOAs between 9% and 13%. Comparing RLOAs from averaged step data across the different walking distances and individual step data, the RLOAs decreased with increased number of steps. The results of this study demonstrate that the DynaPort (R)(MiniMod) system, which allows measurements in real life conditions, is a highly valid tool for assessment of spatio-temporal gait parameters for averaged step data across a walkway length of approximately 20 m in independent living elderly. Gait variability measures and individual step data need to be viewed with caution because of the moderate to low levels of agreement between the two systems. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:444 / 448
页数:5
相关论文
共 23 条
[11]   Accelerometry: A technique for quantifying movement patterns during walking [J].
Kavanagh, Justin J. ;
Menz, Hylton B. .
GAIT & POSTURE, 2008, 28 (01) :1-15
[12]   Concurrent validity of accelerometry to measure gait in Parkinsons Disease [J].
Lord, Sue ;
Rochester, Lynn ;
Baker, Katherine ;
Nieuwboer, Alice .
GAIT & POSTURE, 2008, 27 (02) :357-359
[13]   Concurrent validity and intrasession reliability of the IDEEA accelerometry system for the quantification of spatiotemporal gait parameters [J].
Maffiuletti, Nicola A. ;
Gorelick, Mark ;
Quervain, Ines Kramers-de ;
Bizzini, Mario ;
Munzinger, Jeannette Petrich ;
Tomasetti, Samuele ;
Stacoff, Alex .
GAIT & POSTURE, 2008, 27 (01) :160-163
[14]   The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking [J].
Mansfield, A ;
Lyons, GM .
MEDICAL ENGINEERING & PHYSICS, 2003, 25 (10) :879-885
[15]   Reliability of the GAITRite® walkway system for the quantification of temporo-spatial parameters of gait in young and older people [J].
Menz, HB ;
Latt, MD ;
Tiedemann, A ;
Kwan, MMS ;
Lord, SR .
GAIT & POSTURE, 2004, 20 (01) :20-25
[16]   Age-related differences in walking stability [J].
Menz, HB ;
Lord, SR ;
Fitzpatrick, RC .
AGE AND AGEING, 2003, 32 (02) :137-142
[17]   Test-retest reliability of trunk accelerometry during standing and walking [J].
Moe-Nilssen, R .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1998, 79 (11) :1377-1385
[18]   Measuring step kinematic variability on an instrumented treadmill: how many steps are enough? [J].
Owings, TM ;
Grabiner, MD .
JOURNAL OF BIOMECHANICS, 2003, 36 (08) :1215-1218
[19]   Validity of the GAITRite® walkway system for the measurement of averaged and individual step parameters of gait [J].
Webster, KE ;
Wittwer, JE ;
Feller, JA .
GAIT & POSTURE, 2005, 22 (04) :317-321
[20]  
Woollacott M H, 1997, Phys Ther, V77, P646