Label-Free Electrical Detection of Cardiac Biomarker with Complementary Metal-Oxide Semiconductor-Compatible Silicon Nanowire Sensor Arrays

被引:222
作者
Chua, Jay Huiyi [1 ]
Chee, Ru-Ern [1 ]
Agarwal, Ajay [1 ]
Wong, She Mein [1 ]
Zhang, Guo-Jun [1 ]
机构
[1] Agcy Sci Technol & Res, Inst Microelect, Singapore 117685, Singapore
关键词
TROPONIN-T; DNA HYBRIDIZATION; BIOSENSORS; NANOSENSORS; SPECIFICITY; MOLECULES; INJURY;
D O I
10.1021/ac901157x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Arrays of highly ordered silicon nanowire (SiNW) clusters are fabricated using complementary metal-oxide semiconductor (CMOS) field effect transistor-compatible technology, and the ultrasensitive, label-free, electrical detection of cardiac biomarker in real time using the array sensor is presented. The successful detection of human cardiac troponin-T (cTnT) has been demonstrated in an assay buffer solution of concentration down to 1 fg/mL, as well as in an undiluted human serum environment of concentration as low as 30 fg/mL. The high specificity, selectivity, and swift response time of the SiNWs to the presence of ultralow concentrations of a target protein in a biological analyte solution, even in the presence of a high total protein concentration, paves the way for the development of a medical diagnostic system for point-of-care application that is able to provide an early and accurate indication of cardiac cellular necrosis.
引用
收藏
页码:6266 / 6271
页数:6
相关论文
共 28 条
[11]   Sequence-specific label-free DNA sensors based on silicon nanowires [J].
Li, Z ;
Chen, Y ;
Li, X ;
Kamins, TI ;
Nauka, K ;
Williams, RS .
NANO LETTERS, 2004, 4 (02) :245-247
[12]  
Martins JT, 1996, AM J CLIN PATHOL, V106, P705
[13]   Peptide-nanowire hybrid materials for selective sensing of small molecules [J].
McAlpine, Michael C. ;
Agnew, Heather D. ;
Rohde, Rosemary D. ;
Blanco, Mario ;
Ahmad, Habib ;
Stuparu, Andreea D. ;
Goddard, William A., III ;
Heath, James R. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (29) :9583-9589
[14]  
MullerBardorff M, 1997, CLIN CHEM, V43, P458
[15]   Design considerations of silicon nanowire biosensors [J].
Nair, Pradeep R. ;
Alam, Muhammad A. .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2007, 54 (12) :3400-3408
[16]   Cardiac troponin T levels for risk stratification in acute myocardial ischemia [J].
Ohman, EM ;
Armstrong, PW ;
Christenson, RH ;
Granger, CB ;
Katus, HA ;
Hamm, CW ;
OHanesian, MA ;
Wagner, GS ;
Kleiman, NS ;
Harrell, FE ;
Califf, RM ;
Topol, EJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (18) :1333-1341
[17]   Electrical detection of single viruses [J].
Patolsky, F ;
Zheng, GF ;
Hayden, O ;
Lakadamyali, M ;
Zhuang, XW ;
Lieber, CM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (39) :14017-14022
[18]   Adsorption of bovine serum albumin on nanosized magnetic particles [J].
Peng, ZG ;
Hidajat, K ;
Uddin, MS .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2004, 271 (02) :277-283
[19]   Detection limits for nanoscale biosensors [J].
Sheehan, PE ;
Whitman, LJ .
NANO LETTERS, 2005, 5 (04) :803-807
[20]  
Stern E, 2007, THESIS YALE U