摘要
The growing role of biosensors in analytical chemistry is stimulating research to develop new sensors and improve the merits of existing ones. Particularly important are rapid response, high sensitivity and stability in long operational and storage lifetimes. New enzyme immobilization procedures allow better sensor characteristics and examples of such potentiometric biosensors are presented. Biochemically modified ion-selective membranes, prepared using procedures discussed here, should find wider application, e.g. as sensing elements of optodes. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:528 / 536
页数:9
相关论文
共 29 条
[1]   ELECTROCHEMICAL PERFORMANCE, BIOCOMPATIBILITY, AND ADHESION OF NEW POLYMER MATRICES FOR SOLID-STATE ION SENSORS [J].
CHA, GS ;
LIU, D ;
MEYERHOFF, ME ;
CANTOR, HC ;
MIDGLEY, AR ;
GOLDBERG, HD ;
BROWN, RB .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1666-1672
[2]   POTENTIOMETRIC ION-SELECTIVE AND BIO-SELECTIVE ELECTRODES BASED ON ASYMMETRIC CELLULOSE-ACETATE MEMBRANES [J].
CHA, GS ;
MEYERHOFF, ME .
TALANTA, 1989, 36 (1-2) :271-278
[3]   DESIGN OF IONOPHORE-FREE H+-SELECTIVE SOLVENT POLYMERIC MEMBRANES FOR FURTHER BIOMEDICAL APPLICATIONS [J].
COSOFRET, VV ;
LINDNER, E ;
BUCK, RP ;
KUSY, RP ;
WHITLEY, JQ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 345 (1-2) :169-181
[4]   ELECTROANALYTICAL AND BIOCOMPATIBILITY STUDIES ON CARBOXYLATED POLY(VINYL CHLORIDE) MEMBRANES FOR MICROFABRICATED ARRAY SENSORS [J].
COSOFRET, VV ;
ERDOSY, M ;
BUCK, RP ;
KAO, WJ ;
ANDERSON, JM ;
LINDNER, E ;
NEUMAN, MR .
ANALYST, 1994, 119 (11) :2283-2292
[5]  
Dzwolak W, 1996, CHEM ANAL-WARSAW, V41, P715
[6]   CHEMICAL SENSORS, BIOSENSORS AND THICK-FILM TECHNOLOGY [J].
GALANVIDAL, CA ;
MUNOZ, J ;
DOMINGUEZ, C ;
ALEGRET, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (05) :225-231
[7]   UREA SENSORS BASED ON PVC MEMBRANE PH ELECTRODE [J].
GLAB, S ;
KONCKI, R ;
KOPCZEWSKA, E ;
WALCERZ, I ;
HULANICKI, A .
TALANTA, 1994, 41 (07) :1201-1205
[8]   MEMBRANE TECHNOLOGY AND DYNAMIC-RESPONSE OF ION-SELECTIVE LIQUID-MEMBRANE ELECTRODES [J].
HUSER, M ;
GEHRIG, PM ;
MORF, WE ;
SIMON, W ;
LINDNER, E ;
JENEY, J ;
TOTH, K ;
PUNGOR, E .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1380-1386
[9]  
KAUFFMANN JM, 1991, BIOSENSOR PRINCIPLES, P63
[10]   MICROFIBER MATRIX-SUPPORTED ION-SELECTIVE PVC MEMBRANES [J].
KNOLL, M ;
CAMMANN, K ;
DUMSCHAT, C ;
BORCHARDT, M ;
HOGG, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 20 (01) :1-5