Some unique properties of gas chromatography coupled with atomic-emission detection

被引:34
作者
Andersson, JT [1 ]
机构
[1] Univ Munster, Inst Inorgan & Analyt Chem, D-48149 Munster, Germany
关键词
atomic-emission detector; compound-independent calibration; empirical formula determination; isotope analysis; derivatization;
D O I
10.1007/s00216-002-1236-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The atomic-emission detector in gas chromatography is enormously versatile in applications in analytical chemistry. Its unique properties of high selectivity for most elements and low limits of detection combine to make it the preferred detector for many analytical problems. In this review the stress is laid on the possibility of using it for compound-independent calibration, for determination of the empirical formula of an unknown analyte, for isotope-selective detection, and on derivatization to give AED-active derivatives with advantageous detection properties. Both metals and non-metals are considered and examples of the use of atomic emission detection in real-world analysis are discussed.
引用
收藏
页码:344 / 355
页数:12
相关论文
共 101 条
[82]   Optimization of 15N detection with an atomic emission detector [J].
Stevens, NA ;
Borgerding, MF .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :1083-1086
[83]   GC-AED studies of nicotine fate in a burning cigarette [J].
Stevens, NA ;
Borgerding, MF .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2179-2185
[84]   Effect of column flow rate and sample injection mode on compound-independent calibration using gas chromatography with atomic emission detection [J].
Stevens, NA ;
Borgerding, MF .
ANALYTICAL CHEMISTRY, 1998, 70 (20) :4223-4227
[85]  
Stuff JR, 1999, J MICROCOLUMN SEP, V11, P644, DOI 10.1002/(SICI)1520-667X(199911)11:9<644::AID-MCS2>3.0.CO
[86]  
2-5
[87]   Detailed analysis of sulfur compounds in gasoline range petroleum products with high-resolution gas chromatography atomic emission detection using group-selective chemical treatment [J].
Stumpf, A ;
Tolvaj, K ;
Juhász, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 819 (1-2) :67-74
[88]   CHARACTERIZATION OF A COMPUTERIZED PHOTODIODE ARRAY SPECTROMETER FOR GAS-CHROMATOGRAPHY ATOMIC EMISSION-SPECTROMETRY [J].
SULLIVAN, JJ ;
QUIMBY, BD .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :1034-1043
[89]  
SZELEWSKI M, 1997, SEIFE OELE FETTE WAC, V123, P592
[90]   MEASUREMENTS USING GAS-CHROMATOGRAPHY WITH COELUTION AND DUAL-ISOTOPE ATOMIC EMISSION DETECTION [J].
THOMAS, LC ;
RAMUS, TL .
JOURNAL OF CHROMATOGRAPHY, 1991, 586 (02) :309-313