Recent development in optical chemical sensors coupling with flow injection analysis

被引:25
作者
Bosch Ojeda, Catalina [1 ]
Sanchez Rojas, Fuensanta [1 ]
机构
[1] Univ Malaga, Fac Sci, Dept Analyt Chem, E-29071 Malaga, Spain
关键词
optical chemical sensors; flow injection analysis; applications;
D O I
10.3390/s6101245
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Optical techniques for chemical analysis are well established and sensors based on these techniques are now attracting considerable attention because of their importance in applications such as environmental monitoring, biomedical sensing, and industrial process control. On the other hand, flow injection analysis (FIA) is advisable for the rapid analysis of microliter volume samples and can be interfaced directly to the chemical process. The FIA has become a widespread automatic analytical method for more reasons; mainly due to the simplicity and low cost of the setups, their versatility, and ease of assembling. In this paper, an overview of flow injection determinations by using optical chemical sensors is provided, and instrumentation, sensor design, and applications are discussed. This work summarizes the most relevant manuscripts from 1980 to date referred to analysis using optical chemical sensors in FIA.
引用
收藏
页码:1245 / 1307
页数:63
相关论文
共 213 条
[31]   DNA optical sensor: a rapid method for the detection of DNA hybridization [J].
Chen, X ;
Zhang, XE ;
Chai, YQ ;
Hu, WP ;
Zhang, ZP ;
Zhang, XM ;
Cass, AEG .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4) :451-458
[32]   Flow injection analysis of water vapour based on a fluorosensor [J].
Choi, MMF ;
Tse, OL .
ANALYTICA CHIMICA ACTA, 2000, 423 (02) :229-238
[33]   Nafion-based optical sensor for the determination of selenium in water samples [J].
Coo, LD ;
Martinez, IS .
TALANTA, 2004, 64 (05) :1317-1322
[34]   Nafion-PAN optical chemical sensor: optimization by FIA [J].
Coo, LD ;
Belmonte, CJ .
TALANTA, 2002, 58 (06) :1063-1069
[35]   Sol-gel immobilized room-temperature phosphorescent metal-chelate as luminescent oxygen sensing material [J].
Costa-Fernández, JM ;
Diaz-García, ME ;
Sanz-Medel, A .
ANALYTICA CHIMICA ACTA, 1998, 360 (1-3) :17-26
[36]   Portable fibre optic oxygen sensor based on room-temperature phosphorescence lifetime [J].
Costa-Fernández, JM ;
Bordel, N ;
Campo, JC ;
Ferrero, FJ ;
Pérez, MA ;
Sanz-Medel, A .
MIKROCHIMICA ACTA, 2000, 134 (3-4) :145-152
[37]   A critical comparison of different solid supports to develop room-temperature phosphorescence sensing phases of air moisture [J].
CostaFernandez, JM ;
DiazGarcia, ME ;
SanzMedel, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 38 (1-3) :103-109
[38]   LUMINESCENCE-BASED FIBEROPTIC PROBES [J].
COULET, PR ;
BLUM, LJ ;
GAUTIER, SM .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 11 (1-3) :57-61
[39]  
Cuenca-Trujillo RM, 2002, J AOAC INT, V85, P1268
[40]   A flow injection sensor for simultaneous determination of sulfamethoxazole and trimethoprim by using Sephadex SPC-25 for continuous on-line separation and solid phase UV transduction [J].
de Córdova, MLF ;
Barrales, PO ;
Torné, GR ;
Díaz, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (04) :669-677