Recent development in optical chemical sensors coupling with flow injection analysis

被引:25
作者
Bosch Ojeda, Catalina [1 ]
Sanchez Rojas, Fuensanta [1 ]
机构
[1] Univ Malaga, Fac Sci, Dept Analyt Chem, E-29071 Malaga, Spain
关键词
optical chemical sensors; flow injection analysis; applications;
D O I
10.3390/s6101245
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Optical techniques for chemical analysis are well established and sensors based on these techniques are now attracting considerable attention because of their importance in applications such as environmental monitoring, biomedical sensing, and industrial process control. On the other hand, flow injection analysis (FIA) is advisable for the rapid analysis of microliter volume samples and can be interfaced directly to the chemical process. The FIA has become a widespread automatic analytical method for more reasons; mainly due to the simplicity and low cost of the setups, their versatility, and ease of assembling. In this paper, an overview of flow injection determinations by using optical chemical sensors is provided, and instrumentation, sensor design, and applications are discussed. This work summarizes the most relevant manuscripts from 1980 to date referred to analysis using optical chemical sensors in FIA.
引用
收藏
页码:1245 / 1307
页数:63
相关论文
共 213 条
[71]   Chemiluminescence flow biosensor system for cholesterol with immobilized reagents [J].
Huang Y. ;
Zhang C. ;
Zhang Z. .
Analytical Sciences, 1999, 15 (9) :867-870
[72]   Enzyme modified membranes protected by plasma polymer layers [J].
Janasek, D ;
Spohn, U ;
Kiesow, A ;
Heilmann, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 78 (1-3) :228-231
[73]   A chemiluminometric FIA procedure for the enzymatic determination of L-aspartate [J].
Janasek, D ;
Spohn, U .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 74 (1-3) :163-167
[74]   Novel chemiluminometric H2O2 sensors for the selective flow injection analysis [J].
Janasek, D ;
Spohn, U ;
Beckmann, D .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 51 (1-3) :107-113
[75]   Chemiluminometric Flow Injection Analysis procedures for the enzymatic determination of L-alanine, α-ketoglutarate and L-glutamate [J].
Janasek, D ;
Spohn, U .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (02) :123-129
[76]   Direct determination of copper in urine using a sol-gel optical sensor coupled to a multicommutated flow system [J].
Jerónimo, PCA ;
Araújo, AN ;
Montenegro, MCBSM ;
Pasquini, C ;
Raimundo, IM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (01) :108-114
[77]   A biochemical microdevice with an integrated chemiluminescence detector [J].
Jorgensen, AM ;
Mogensen, KB ;
Kutter, JP ;
Geschke, O .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 90 (1-3) :15-21
[78]   Chemiluminescence detection of peroxynitrite with flow injection [J].
Kang, D ;
Zhou, YK .
INTERNATIONAL CONFERENCE ON SENSOR TECHNOLOGY (ISTC 2001), PROCEEDINGS, 2001, 4414 :104-107
[79]   TRENDS IN BIOSENSOR RESEARCH-AND-DEVELOPMENT [J].
KARUBE, I ;
YOKOYAMA, K .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 13 (1-3) :12-15
[80]   Flow-injection determination of L-histidine with an immobilized histidine oxidase from Brevibacillus borstelensis KAIT-B-022 and chemiluminescence detection [J].
Kiba, N ;
Koga, A ;
Tachibana, M ;
Tani, K ;
Koizumi, H ;
Koyama, T ;
Yamamura, A ;
Matsumoto, K ;
Okuda, T ;
Yokotsuka, K .
ANALYTICAL SCIENCES, 2006, 22 (01) :95-98