Determination of amino acids in overlapped capillary electrophoresis peaks by means of partial least-squares regression

被引:38
作者
Latorre, RM [1 ]
Saurina, J [1 ]
Hernández-Cassou, S [1 ]
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
capillary electrophoresis; least-squares analysis; chemometrics; amino acids; naphthoquinonesulfonate;
D O I
10.1016/S0021-9673(99)00853-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Amino acid derivatives of 1,2-naphthoquinone-4-sulfonate (NQS) can be separated by capillary electrophoresis at 30 kV in a fused-silica capillary by using a 40 mM sodium tetraborate-isopropanol (3:1, v/v) solution as background electrolyte. This procedure was suitable for the most common amino acids. However, the peaks of three amino acids (phenylalanine, isoleucine and tyrosine) were only partially resolved and peaks of histidine and leucine derivatives overlapped completely. Partial least-squares regression (PLS) may overcome the lack of selectivity for these amino acids. Spectroelectropherograms of the corresponding amino acid derivative peaks were monitored with a diode-array spectrophotometer in the range 225 to 540 nm. Both spectra and electropherograms can be used as multivariate data for further analysis. In general, the best predictions were obtained using the time domain. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:331 / 340
页数:10
相关论文
共 43 条
[1]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[2]  
Baker D. R., 1995, CAPILLARY ELECTROPHO
[3]   RESOLUTION OF A COELUTING CHROMATOGRAPHIC PAIR USING KALMAN FILTERING [J].
BARKER, T ;
BROWN, SD .
JOURNAL OF CHROMATOGRAPHY, 1989, 469 :77-90
[4]   AN INTRODUCTION TO MULTIVARIATE CALIBRATION AND ANALYSIS [J].
BEEBE, KR ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1987, 59 (17) :A1007-+
[5]   MULTICOMPONENT CALIBRATION AND ANALYSIS IN LIQUID-CHROMATOGRAPHY [J].
CECIL, TL ;
POE, RB ;
RUTAN, SC .
ANALYTICA CHIMICA ACTA, 1991, 250 (01) :37-44
[6]   CORRECTION FOR FLUORESCENCE RESPONSE SHIFTS IN POLYAROMATIC HYDROCARBON MIXTURES WITH AN INNOVATIONS-BASED KALMAN FILTER METHOD [J].
CECIL, TL ;
RUTAN, SC .
ANALYTICAL CHEMISTRY, 1990, 62 (18) :1998-2004
[7]   MULTICOMPONENT ANALYSIS OF HIGHLY OVERLAPPED HPLC PEAKS USING MULTIWAVELENGTH DIODE-ARRAY DETECTION [J].
CLADERA, A ;
GOMEZ, E ;
ESTELA, JM ;
CERDA, V .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1992, 30 (11) :453-458
[8]  
DAVIES JS, 1985, AMINO ACIDS PEPTIDES
[9]   Purity assessment and resolution of tetracycline hydrochloride samples analysed using high-performance liquid chromatography with diode array detection [J].
De Braekeleer, K ;
de Juan, A ;
Massart, DL .
JOURNAL OF CHROMATOGRAPHY A, 1999, 832 (1-2) :67-86
[10]  
DELAPENA AM, 1990, ANAL CHIM ACTA, V234, P263