In situ measurement of articular cartilage deformation in intact femoropatellar joints under static loading

被引:162
作者
Herberhold, C
Faber, S
Stammberger, T
Steinlechner, M
Putz, R
Englmeier, KH
Reiser, M
Eckstein, F
机构
[1] Univ Munich, Inst Anat, Musculoskeletal Res Grp, D-80336 Munich, Germany
[2] Univ Munich, Klinikum Grosshadern, Inst Radiol Diagnost, D-81377 Munich, Germany
[3] GSF Forschungszentrum Umwelt & Gesundheit Neuherb, Inst Med Informat & Syst Forsch, D-85764 Oberschleissheim, Germany
[4] Univ Innsbruck, Inst Gerichtliche Med, A-6020 Innsbruck, Austria
关键词
articular cartilage; cartilage mechanics; MR imaging; joint loading;
D O I
10.1016/S0021-9290(99)00130-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The deformational behavior of articular cartilage has been investigated in confined and unconfined compression experiments and indentation tests, but to date there exist no reliable data on the in situ deformation of the cartilage during static loading. The objective of the current study was to perform a systematic study into cartilage compression of intact human femoro-patellar joints under short- and long-term static loading with MR imaging. A non-metallic pneumatic pressure device was used to apply loads of 150% body weight to six joints within the extremity coil of an MRI scanner. The cartilage was delineated during the compression experiment with previously validated 2D and 3D fat-suppressed gradient echo sequences. We observed a mean (maximal) in situ deformation of 44% (57%) in patellar cartilage after 3 1/2 h of loading (mean contact pressure 3.6 MPa), the femoral cartilage showing a smaller amount of deformation than the patella. However, only around 7% of the final deformation (3% absolute deformation) occurred during the first minute of loading. A 43% fluid loss from the interstitial patellar matrix was recorded, the initial fluid flux being 0.217 +/- 0.083 mu m/s, and a high inter-individual variability of the deformational behavior (coefficients of variation 11-38%). In conjunction with finite-element analyses, these data may be used to compute the load partitioning between the solid matrix and fluid phase, and to elucidate the etiologic factors relevant in mechanically induced osteoarthritis. They can also provide direct estimates of the mechanical strain to be encountered by cartilage transplants. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1287 / 1295
页数:9
相关论文
共 35 条
  • [1] INVITRO MEASUREMENT OF ARTICULAR-CARTILAGE DEFORMATIONS IN THE INTACT HUMAN HIP-JOINT UNDER LOAD
    ARMSTRONG, CG
    BAHRANI, AS
    GARDNER, DL
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (05) : 744 - 755
  • [2] AN ASYMPTOTIC SOLUTION FOR THE CONTACT OF 2 BIPHASIC CARTILAGE LAYERS
    ATESHIAN, GA
    LAI, WM
    ZHU, WB
    MOW, VC
    [J]. JOURNAL OF BIOMECHANICS, 1994, 27 (11) : 1347 - 1360
  • [3] A THEORETICAL SOLUTION FOR THE FRICTIONLESS ROLLING-CONTACT OF CYLINDRICAL BIPHASIC ARTICULAR-CARTILAGE LAYERS
    ATESHIAN, GA
    WANG, HQ
    [J]. JOURNAL OF BIOMECHANICS, 1995, 28 (11) : 1341 - 1355
  • [4] INTERSPECIES COMPARISONS OF INSITU INTRINSIC MECHANICAL-PROPERTIES OF DISTAL FEMORAL CARTILAGE
    ATHANASIOU, KA
    ROSENWASSER, MP
    BUCKWALTER, JA
    MALININ, TI
    MOW, VC
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (03) : 330 - 340
  • [5] Incompressibility of the solid matrix of articular cartilage under high hydrostatic pressures
    Bachrach, NM
    Mow, VC
    Guilak, F
    [J]. JOURNAL OF BIOMECHANICS, 1998, 31 (05) : 445 - 451
  • [6] Knee cartilage topography, thickness, and contact areas from MRI: in-vitro calibration and in-vivo measurements
    Cohen, ZA
    McCarthy, DM
    Kwak, SD
    Legrand, P
    Fogarasi, F
    Ciaccio, EJ
    Ateshian, GA
    [J]. OSTEOARTHRITIS AND CARTILAGE, 1999, 7 (01) : 95 - 109
  • [7] A contact finite element formulation for biological soft hydrated tissues
    Donzelli, PS
    Spilker, RL
    [J]. COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 1998, 153 (1-2) : 63 - 79
  • [8] Eckstein F, 1998, CLIN ORTHOP RELAT R, P137
  • [9] Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondro-crassometry (3D MR-CCM)
    Eckstein, F
    Gavazzeni, A
    Sittek, H
    Haubner, M
    Losch, A
    Milz, S
    Englmeier, KH
    Schulte, E
    Putz, R
    Reiser, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) : 256 - 265
  • [10] Non-invasive determination of cartilage thickness throughout joint surfaces using magnetic resonance imaging
    Eckstein, F
    Adam, C
    Sittek, H
    Becker, C
    Milz, S
    Schulte, E
    Reiser, M
    Putz, R
    [J]. JOURNAL OF BIOMECHANICS, 1997, 30 (03) : 285 - 289