Characterization of bonds formed between platelet factor 4 and negatively charged drugs using single molecule force spectroscopy

被引:13
作者
Block, Stephan [1 ]
Greinacher, Andreas [2 ]
Helm, Christiane A. [3 ]
Delcea, Mihaela [1 ]
机构
[1] ZIK HIKE Zentrum Innovat Kompetenz, D-17489 Greifswald, Germany
[2] Inst Immunol & Transfus Med, D-17475 Greifswald, Germany
[3] Ernst Moritz Arndt Univ Greifswald, Inst Phys, D-17487 Greifswald, Germany
关键词
HEPARIN-INDUCED THROMBOCYTOPENIA; PLATELET FACTOR-IV; MICROSCOPE CANTILEVERS; SPRING CONSTANT; BINDING-SITES; ANTIBODIES; POLYSACCHARIDES; COMPLEX; IMMUNOGENICITY; CALIBRATION;
D O I
10.1039/c3sm52609g
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Immunogenicity (i.e., the ability to initiate immune reactions) is one of the major challenges for the development of new drugs, as it may turn the developed drug therapeutically ineffective or cause severe immune-related effects. Using single molecule force spectroscopy, we study rupture forces between the positively charged, endogenous protein platelet factor 4 (PF4; also known as CXC chemokine ligand 4, CXCL4) and the antithrombotic drug heparin and other negatively charged glycosaminoglycans (GAGs), which are known to form immunogenic PF4/GAG-complexes (e. g., heparin and dextran sulfate) as well as non-immunogenic complexes (e. g., chondroitin sulfate A). Our measurements suggest that the average number of sulfate groups per monosaccharide unit (i.e., the degree of sulfation DS) does not affect the unbinding characteristics of single PF4/GAG-bonds (reaction coordinate x(0) = 2.2 +/- 0.2 angstrom, energy barrier Delta G approximate to -1 k(B)T). However, the average number of GAG bonds formed to a single PF4 molecule increases with increasing DS as indicated by a rising frequency of unbinding events, suggesting a multivalent binding scheme between PF4 and GAGs. Our studies show that at least three GAG bonds have to be formed to each PF4 molecule to induce epitope formation on the PF4/GAG-complex to which PF4/GAG-complex specific antibodies bind. Hence, GAG-based drugs that form less than three bonds per PF4 molecule are unlikely to constitute PF4/drug-complexes that are of immunologic relevance.
引用
收藏
页码:2775 / 2784
页数:10
相关论文
共 54 条
[31]   Measuring the spring constant of atomic force microscope cantilevers:: thermal fluctuations and other methods [J].
Lévy, R ;
Maaloum, M .
NANOTECHNOLOGY, 2002, 13 (01) :33-37
[32]   THE INTERACTION OF PLATELET FACTOR-4 WITH HEPARINS OF DIFFERENT CHAIN-LENGTH [J].
MARSHALL, SE ;
LUSCOMBE, M ;
PEPPER, DS ;
HOLBROOK, JJ .
BIOCHIMICA ET BIOPHYSICA ACTA, 1984, 797 (01) :34-39
[33]   Stretching single polysaccharides and proteins using atomic force microscopy [J].
Marszalek, Piotr E. ;
Dufrene, Yves F. .
CHEMICAL SOCIETY REVIEWS, 2012, 41 (09) :3523-3534
[34]   Potentials of mean force between ionizable amino acid side chains in water [J].
Masunov, A ;
Lazaridis, T .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (07) :1722-1730
[35]   HEPARIN-BINDING TO PLATELET FACTOR-IV - AN NMR AND SITE-DIRECTED MUTAGENESIS STUDY - ARGININE RESIDUES ARE CRUCIAL FOR BINDING [J].
MAYO, KH ;
ILYINA, E ;
ROONGTA, V ;
DUNDAS, M ;
JOSEPH, J ;
LAI, CK ;
MAIONE, T ;
DALY, TJ .
BIOCHEMICAL JOURNAL, 1995, 312 :357-365
[36]   Heparin dodecasaccharide binding to platelet factor-4 and growth-related protein-α -: Induction of a partially folded state and implications for heparin-induced thrombocytopenia [J].
Mikhailov, D ;
Young, HC ;
Linhardt, RJ ;
Mayo, KH .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1999, 274 (36) :25317-25329
[37]   Atomic force microscopy as a multifunctional molecular toolbox in nanobiotechnology [J].
Mueller, Daniel J. ;
Dufrene, Yves F. .
NATURE NANOTECHNOLOGY, 2008, 3 (05) :261-269
[38]   Force and function: probing proteins with AFM-based force spectroscopy [J].
Puchner, Elias M. ;
Gaub, Hermann E. .
CURRENT OPINION IN STRUCTURAL BIOLOGY, 2009, 19 (05) :605-614
[39]   Single molecule force spectroscopy on polysaccharides by atomic force microscopy [J].
Rief, M ;
Oesterhelt, F ;
Heymann, B ;
Gaub, HE .
SCIENCE, 1997, 275 (5304) :1295-1297
[40]   Calibration of rectangular atomic force microscope cantilevers [J].
Sader, JE ;
Chon, JWM ;
Mulvaney, P .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (10) :3967-3969