A motion-incorporated reconstruction method for gated PET studies

被引:193
作者
Qiao, Feng [1 ]
Pan, Tinsu
Clark, John W., Jr.
Mawlawi, Osama R.
机构
[1] Rice Univ, Dept Elect & Comp Engn, Houston, TX 77005 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
关键词
D O I
10.1088/0031-9155/51/15/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cardiac and respiratory motion artefacts in PET imaging have been traditionally resolved by acquiring the data in gated mode. However, gated PET images are usually characterized by high noise content due to their low photon statistics. In this paper, we present a novel 4D model for the PET imaging system, which can incorporate motion information to generate a motion-free image with all acquired data. A computer simulation and a phantom study were conducted to test the performance of this approach. The computer simulation was based on a digital phantom that was continuously scaled during data acquisition. The phantom study, on the other hand, used two spheres in a tank of water, all of which were filled with F-18 water. One of the spheres was stationary while the other moved in a sinusoidal fashion to simulate tumour motion in the thorax. Data were acquired using both 4D CT and gated PET. Motion information was derived from the 4D CT images and then used in the 4D PET model. Both studies showed that this 4D PET model had a good motion-compensating capability. In the phantom study, this approach reduced quantification error of the radioactivity concentration by 95% when compared to a corresponding static acquisition, while signal-to-noise ratio was improved by 210% when compared to a corresponding gated image.
引用
收藏
页码:3769 / 3783
页数:15
相关论文
共 28 条
  • [1] BRANKOV JG, 2002, 2002 S C REC IEEE NU, V3, P1380
  • [2] An accurate method for correction of head movement in PET
    Bühler, P
    Just, U
    Will, E
    Kotzerke, J
    van den Hoff, J
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (09) : 1176 - 1185
  • [3] A LIMITED MEMORY ALGORITHM FOR BOUND CONSTRAINED OPTIMIZATION
    BYRD, RH
    LU, PH
    NOCEDAL, J
    ZHU, CY
    [J]. SIAM JOURNAL ON SCIENTIFIC COMPUTING, 1995, 16 (05) : 1190 - 1208
  • [4] Three-dimensional motion estimation with image reconstruction for gated cardiac ECT
    Cao, ZX
    Gilland, DR
    Mari, BA
    Jaszczak, RJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) : 384 - 388
  • [5] FESSLER JA, FREE IMAGE RECONSTRU
  • [6] A novel platform simulating irregular motion to enhance assessment of respiration-correlated radiation therapy procedures
    Fitzpatrick, Mathew J.
    Starkschall, George
    Balter, Peter
    Antolak, John A.
    Guerrero, Thomas
    Nelson, Christopher
    Keall, Paul
    Mohan, Radhe
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (01): : 13 - 21
  • [7] Correction for head movements in positron emission tomography using an optical motion-tracking system
    Fulton, RR
    Meikle, SR
    Eberl, S
    Pfeiffer, J
    Constable, CJ
    Fulham, MJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) : 116 - 123
  • [8] Simultaneous reconstruction and motion estimation for gated cardiac ECT
    Gilland, DR
    Mair, BA
    Bowsher, JE
    Jaszczak, RJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2344 - 2349
  • [9] Gilland DR, 2005, P INT M FULL 3 DIM I, P303
  • [10] Motion-compensated reconstruction of tomographic image sequences
    Gravier, EJ
    Yang, YY
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 51 - 56