Correction for head movements in positron emission tomography using an optical motion-tracking system

被引:131
作者
Fulton, RR [1 ]
Meikle, SR
Eberl, S
Pfeiffer, J
Constable, CJ
Fulham, MJ
机构
[1] Royal Prince Alfred Hosp, Dept PET & Nucl Med, Sydney, NSW, Australia
[2] Fachhsch Aachen, Aachen, Germany
[3] Forschungszentrum Julich, Inst Med, Julich, Germany
关键词
motion correction; motion tracking; positron emission tomography (PET);
D O I
10.1109/TNS.2002.998691
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Methods capable of correcting for head motion in all six degrees of freedom have been proposed for positron emission tomography (PET) brain imaging but not yet demonstrated in human studies. These methods rely on the accurate measurement of head motion in relation to the reconstruction coordinate frame. We present methodology for the direct calibration of an optical motion-tracking system to the reconstruction coordinate frame using paired coordinate measurements obtained simultaneously from a PET scanner and tracking system. We also describe the implementation of motion correction, based on the multiple acquisition frame method originally described by Picard and Thompson, using data provided by the motion tracking system. Effective compensation for multiple six-degree-of-freedom movements is demonstrated in dynamic PET scans of the Hoffman brain phantom and a normal volunteer. We conclude that reduced distortion and improved quantitative accuracy can be achieved with this method in PET brain studies degraded by head movements.
引用
收藏
页码:116 / 123
页数:8
相关论文
共 10 条
[1]  
DAUBE-WITHERSPOON M E, 1990, Journal of Nuclear Medicine, V31, P816
[2]   A practical 3D tomographic method for correcting patient head motion in clinical SPECT [J].
Fulton, RR ;
Eberl, S ;
Meikle, SR ;
Hutton, BF ;
Braun, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :667-672
[3]  
GREEN MV, 1994, J NUCL MED, V35, P1538
[4]   3-D PHANTOM TO SIMULATE CEREBRAL BLOOD-FLOW AND METABOLIC IMAGES FOR PET [J].
HOFFMAN, EJ ;
CUTLER, PD ;
DIGBY, WM ;
MAZZIOTTA, JC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :616-620
[5]  
Hooper PK, 1996, J NUCL MED, V37, P128
[6]   CLOSED-FORM SOLUTION OF ABSOLUTE ORIENTATION USING UNIT QUATERNIONS [J].
HORN, BKP .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (04) :629-642
[7]   Implementation and performance of an optical motion tracking system for high resolution brain PET imaging [J].
Lopresti, BJ ;
Russo, A ;
Jones, WF ;
Fisher, T ;
Crouch, DG ;
Altenburger, DE ;
Townsend, DW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) :2059-2067
[8]   Simultaneous emission and transmission (SET) scanning in neurological PET studies [J].
Meikle, SR ;
Eberl, S ;
Hooper, PK ;
Fulham, MJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (03) :487-497
[9]   Compensation methods for head motion detected during PET imaging [J].
Menke, M ;
Atkins, MS ;
Buckley, KR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (01) :310-317
[10]   Motion correction of PET images using multiple acquisition frames [J].
Picard, Y ;
Thompson, CJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :137-144